Other fall to lower level 11 to 15 feet · Fractures and other injuries, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Seatex - El Campo Plant, 1102 North Blue Creek Road, EL CAMPO, TEXAS 77437
on — Fractures and other injuries, unspecified, affecting the multiple body parts, n.e.c..
Watch Seatex - El Campo Plant — freeGet an email when a new federal OSHA severe-injury report for Seatex - El Campo Plant is published. One employer, no account, unsubscribe in one click.
Final narrative
Employees were cleaning around elevated water pipes. An employee was in an aerial platform being elevated when the platform contacted a pipe, breaking it. The flow of water from the broken pipe struck the employee, causing him to lose balance and fall to ground level 10 to 12 feet below. He suffered a head laceration, a broken collarbone, and a neck injury; he was hospitalized, undergoing surgery.
HospitalizedMultiple body parts, n.e.c.Aerial lifts, scissor lifts-except truck-mounted
The employee was on top of a rail car to level the grain that was deposited into the car when they fell 13-15 feet to the ground. The employee sustained a right leg fracture.
An employee was on an extension ladder installing a satellite dish on a roof when they fell approximately 12-15 feet to the ground. The employee sustained fractures.
An employee was setting a 5-foot pry bar into a precast concrete slab and stood on the end of the pry bar to move the slab into place. The pry bar slipped out causing the employee to fall backward 15.5 feet to the dirt ground. The employee was hospitalized with a broken leg.
An employee was on a step ladder to measure and mark a crane rail for modification. The employee fell approximately 12 to 15 feet to the ground, resulting in a fractured right hip.
An employee was on a trailer securing a load of logs when they fell approximately 9-12 feet to the ground. The employee sustained brain hemorrhaging and lacerations to the thigh and above the eye. The employee was hospitalized.
More severe injuries in this industry (NAICS 325110)
An employee was applying pressure to a tank car loaded with caustic soda solution for post-load leak testing. He twisted the valve plug to check it for leaks when it broke free, releasing the caustic soda solution through the opening. The employee suffered chemical burns to both eyes and to his respiratory tract.
Employees were setting up an 8-inch sewer PVC pipe line. An employee was removing/rolling a scrap PVC pipe off the conveyor when their little fingertip was crushed between the end of the PVC pipe and the post for the overhead bus stop guard (fixed guard). The employee was hospitalized and required surgery.
An employee was walking by an equipment battery (tank battery) when a leak occurred around a heater that caused a flash fire. He was wearing flame-resistant clothing and sustained burns to his palms and back.
Two employees were removing a recirculation pump from service at an evaporator. They were disconnecting pump flanges and couplings from the motor when boiling water burst out from the system. Both employees sustained second-degree burns to the chest, stomach, and arms.
On December 9, 2024, an employee was cleaning out a mixtruder. While he was retrieving some residual pieces of silicone left inside, its rotating blades caught the fingers of his right hand resulting in amputation of all four fingers. The thumb was left intact.
After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.
An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.