Struck by running powered equipment during maintenance, cleaning, testing · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at HN Precision, 601 Skokie Hwy, LAKE BLUFF, ILLINOIS 60044
on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..
Final narrative
A part jammed in a rotary machine. While an employee was removing it, the machine's piston came down on his finger, resulting in an amputation to the top portion of the left little finger. The machine was unguarded at the time of the incident.
HospitalizedAmputation Other finger(s) n.e.c. Metal, woodworking, and special material machinery unspecified
A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.
A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.
More severe injuries in this industry (NAICS 332721)
An employee was raising a lift to fix a server box when the lift caught the edge of the box and it fell. The employee's finger was pinched by the box, resulting in a fingertip amputation.
An employee was working to remove an extra slug from a press. The employee pushed the eject button, then tried to catch the slug. When the release came out, it pinched the employee's right index finger against the slug, resulting in an amputation to the finger.
On September 5, 2025, at approximately 7:35 AM, a temporary employee was at the engine block rollover machine. Their left index fingertip was caught and amputated between a pneumatic part and a guard.
An employee was cleaning coolant tank magnets used to separate metal grinding mud from the coolant tanks. As the employee went to separate two magnets they snapped back together and crushed his right thumb, resulting in amputation of the top of the thumb.
A maintenance technician was measuring the width on a metal compressor's stroke length when their finger was pinched in the machine. The employee was hospitalized with lacerations to their finger.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.