Caught or wedged between objects nonrunning · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at J.B. Hunt Transport Inc., 4012 S. Kedzie Ave., CHICAGO, ILLINOIS 60632
on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..
Final narrative
On April 23, 2024, at approximately 7:30 PM, a driver was picking up a trailer at a rail yard. The employee was using a crowbar and hammer to adjust the pins of the chassis to allow the intermodal container to sit on the chassis. The container shifted and the employee's left hand was caught between the container and chassis, resulting in a partial amputation of their middle, ring, and little fingers.
Amputation Other finger(s) n.e.c. Shipping containers
An employee had pulled his semi-trailer over at a rest stop because the trailer door had opened. He was trying to pull down the door, gripping a strap with one hand and the trailer grip handle with the other hand, when he fell to the ground 2-3 feet below. He suffered a broken right shoulder, a fracture to a right-side middle rib, a punctured right lung, and a swollen esophagus.
An employee was struck by a large paper roll upon opening semi-trailer doors after the load shifted during transport. The employee sustained a fractured right leg and left toes.
An employee was attempting to pull a fifth wheel below a semi-trailer. It was tight, so he grabbed a puller to use on the wheel. In the process, the puller slipped and the employee fell to the ground on his right side, resulting in a fractured right hip that required surgery.
On June 21, 2023, at approximately 11:45 a.m., an employee climbed a dock plate at a customer site to avoid heavy rain. While reaching with his left hand to support his footing, his gloved left hand contacted a powered conveyor chain that was next to the dock area. His left ring fingertip was medically amputated.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
More severe injuries in this industry (NAICS 484121)
An employee fell while exiting a trailer. The employee landed on their left side on the pavement, suffering multiple broken ribs on the left side. The employee was hospitalized.
An employee was hooking up a set of 28-foot trailers, attaching a converter dolly to the lead trailer's pintle hook. He backed up the lead trailer and parked it a foot from the converter dolly, then lifted the converter dolly and rolled it to the lead trailer to set it onto the hook. The converter dolly kicked up, and the employee's left hand was caught between it and the trailer. He suffered a severe laceration to the palm between the ring finger and middle finger.
An employee was cleaning the windshield of his truck. When he stepped down from the truck, he lost balance and reached to catch himself using the side mirror. The impact fractured his left wrist. The employee was hospitalized and required surgery.
An employee was standing on the DOT bumper on the back of a standard 53-foot trailer. The employee lost his footing and his grip on the handle bar, and fell approximately 42 inches to the ground. The employee was hospitalized with a fractured left hip/femur.
A driver was making a delivery. As he was climbing onto his trailer to get boxes, the strap he was using to pull himself up broke. He fell from the back of the trailer to the ground, landing on his right leg and breaking his femur.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was driving a boom lift (in the lowered position) in an exterior dock area. The lift s left wheels rolled onto base plates that covered a 3-foot-deep sump pit. The base plates failed, and one side of the lift dropped. The employee's left leg was caught under the lift basket, and he suffered a fracture to the lower leg including the ankle.