105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Fabco-Air, Inc.

Struck by running powered equipment during maintenance, cleaning, testing · Amputations involving bone loss

Federal OSHA recorded a severe workplace injury at Fabco-Air, Inc., 3716 N.E. 49TH Ave., GAINESVILLE, FLORIDA 32609 on — Amputations involving bone loss, affecting the Other finger(s) n.e.c..

On May 12, 2024, at approximately 7:00 PM, an employee was conducting maintenance/repairs to a conveyor belt when the conveyor cycled and malfunctioned, amputating the employee's left middle finger. The conveyor was energized at the time.

Amputation Other finger(s) n.e.c. Conveyors belt, slot, chain

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

CFL USA, LLC

A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Milwaukee Valve Company, LLC

An employee was repositioning a large casting with a chain. The chain slipped and landed on his hand, resulting in hospitalization with a fracture to his upper arm and a crushing injury to his thumb.

Nibco, Inc.

An employee was performing a machine set-up and had installed one set of holding jaws. His right index finger became caught in an air vise while re-clamping a part. The employee sustained a partial amputation above the fingernail.

Stellix Group, Inc.

Two employees were re-packing a butterfly valve. The valve was being held by a crane. An employee added air to the valve to close it. The valve moved and the other employee reached to steady it. His thumb was caught in the valve and the thumb tip was amputated.

Vault Pressure Control

An employee was preparing to install a production tree/master valve. The employee grabbed the bull plug and shook the production tree into place. The well blew out on the casing side. The pressure caused the production tree to fall over onto the employee, resulting in a fractured right leg.

Total Valve Systems

An employee was manually moving a 30-pound valve. When he sat the valve down, it crushed his left index fingertip just above the nail and amputated it.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.