105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

AGR International, Inc.

Struck by running powered equipment unspecified · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at AGR International, Inc., 615 Whitestown Road, BUTLER, PENNSYLVANIA 16001 on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).

An employee was retrieving a bottle from inside a permeability plugging tester machine when the machine began moving. The employee sustained a left ring fingertip amputation.

Amputation Finger or thumb tip(s), nail(s) Other product testing, inspecting, and diagnostic machinery

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

TABER EXTRUSIONS, LLC

An employee's left arm was caught in the fingers or jaws of the head stretcher machine, resulting in a laceration. The employee was hospitalized.

American Flowform and Machining, LLC

Two employees were setting up a mandrel in the spindle of a machine. The mandrel was side-shifted while an employee's hand was on the mast of a powered industrial truck. The employee suffered crushing injuries that resulted in amputations to the middle and ring fingertips.

Omya Inc.

An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.

Teledyne Benthos, Inc.

An employee was using a hand tool to cut a mooring line at a marina to demonstrate equipment to customers. The hand tool broke and struck the employee in their left eye, lacerating the cornea.

NSI-MI TECHNOLOGIES, LLC

An employee had just gone through a roll-up door and closed it. The rope used to pull the door down caught her foot and she fell, breaking her left kneecap.

Alstom

An employee was changing the bottom die on a hydraulic power crimper. Their left thumb was crushed between the two die components when the crimper engaged, resulting in thumb fractures.

TRECE, INC.

A chemist was finishing a reaction. He added paraformaldehyde to a Grignard solution in a 5-liter glass jacketed reactor. The reaction mixture over-pressurized and the reactor shattered, spreading shards of glass throughout the room. The chemist sustained lacerations to the chest and thigh.

Hooks & Associates Inc

At 8:50 a.m. on October 6, 20201, an employee was positioned behind a metal shear to help hold a piece of material about to be cut. As the shearing machine was engaged, its vertically moving backstop pinched the employee's left arm against a table below, in place to catch clippings. The employee suffered broken bones just above the wrist and was hospitalized.

Main Line Clinical Labs

An employee was closing a door when the door closed on their right index finger, resulting in a fingertip amputation.

Ardent Mills

An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.

Zimmerman & Herr

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.

McAneny Brothers, Inc.

An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.

Metz Culinary Management LLC

An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.