Fall on same level due to slip or trip · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at EUROFINS ENVIRONMENT TESTING SOUTHEAST, LLC, 3080 Presidential Drive, ATLANTA, GEORGIA 30340
on — Fractures , affecting the Hip joint(s).
Watch Eurofins Environment Testing Southeast, LLC — freeGet an email when a new federal OSHA severe-injury report for Eurofins Environment Testing Southeast, LLC is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee tripped on an anti-fatigue mat and fell on her left hip resulting in a fractured hip.
Hospitalized Hip joint(s) Other constructed surface
An employee was installing fence posts when they stepped into a recently dug hole that was not visible due to rainfall. The employee's leg was fractured.
The injured employee was standing behind a table. She jumped out to scare another employee, but tripped and fell on the tile floor, injuring her right ankle/foot. She was hospitalized with a dislocated ankle that required surgery.
An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.
An employee was operating a horizontal belt sanding machine that rotates a metal sanding belt. The employee switched hands while the belt transitioned from left to right. When the machine's speed was adjusted, the employee s left hand was pulled into the machine and crushed. The employee was hospitalized and required surgery.
An X-ray machine had lost power and an employee went to replace the power supply. While replacing a cable on the power supply assembly, the employee's right hand contacted the grounding terminals coming out of the back of the power supply assembly and they received an electric shock. The employee was hospitalized.
On March 19, 2025, an employee was retrieving a medical specimen from the back of a vehicle. When he turned to enter the building, he either tripped over something or lost his footing and fell due to an incline in the pavement. The employee was hospitalized with a head abrasion and injuries to his right shoulder and right hip.
Employees were pulling a chemical sample from a device (sample port). The sample wouldn't come out because there were two samples in the port. The employees then turned off and deenergized the machine to 0 pounds per square inch. They unscrewed the top of the machine to retrieve the stuck samples when a small amount of pressure caused liquid to squirt out and onto one of the employee's face shields as the lid was removed. The employee was hospitalized due to chemical exposure.
An employee was walking around a boiler recovery tank when they stepped into an uncovered U-drain filled with hot water. The employee sustained second-degree burns to their right leg and the top of their foot.
An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.
During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.
An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.