Injured by object held or wielded by person · Nonfatal 'crushing' injuries
At a glance
Federal OSHA recorded a severe workplace injury
at Harmony Castings, 251 Perry Highway, HARMONY, PENNSYLVANIA 16037
on — Nonfatal 'crushing' injuries, affecting the Finger or thumb tip(s), nail(s).
Final narrative
An employee was using a pry bar to separate a flask (two large metal boxes) when the pry bar slipped and the top part came down and crushed their left index fingertip.
Hospitalized Finger or thumb tip(s), nail(s) Crowbars
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
An employee was disassembling a pressurized unit using a driver drill. When the unit was disassembled, it caused a kickback from the tube head, causing the drill to strike the employee's left forearm. They sustained a diaphyseal fracture to their left radius and ulna, which required surgery.
While working at a customer's residence, an employee was cutting tape with a box cutter to wrap insulation for a piece of pipe. The box cutter struck a hardened object within the wall causing it to bounce back and puncture the employee's right eye. The employee was hospitalized.
An employee was using the pipe-and-wrench method to loosen a seized bolt on a roof truss. A technician from another company was on the other side of the truss doing the same action with the same method. The employee's socket slipped off the bolt and his left hand was crushed against the truss, resulting in injuries to the index and little fingers, requiring hospitalization, surgery, and amputation of the index finger.
More severe injuries in this industry (NAICS 331523)
An employee was adjusting the oscillator pressure injector on a die-cast machine when his right thumb contacted the adjustment handle. The machine oscillated and closed on his right thumb. The tip of the thumb was pinched and amputated between the die and the handle.
An employee in the melt department was getting ready to put a recirculation pump into the pump housing area. He first put the pump in a cabinet to warm it up to avoid thermal shock. It shifted and the cold refractory contacted the hot metal. Molten metal contacted the employee, resulting in third-degree burns between their knee(s) and ankle(s). The employee was wearing some personal protective equipment (PPE) at the time but this was breached by the molten metal.
On May 15, 2025, an employee was assisting with troubleshooting an issue with a die in a die casting machine. While unjamming the machine, the employee's finger was caught between a section of the die and a wooden spacer. The employee's left middle fingertip was amputated.
An employee was checking the die casting machine when the cavity access door closed behind him and the employee sustained eight fractured ribs. The employee was hospitalized.
An employee was using a vertical band saw to cut a piece of square metal tubing when their left hand contacted the saw blade and their middle finger was amputated.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.