105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Oxford Airport Technical Services

Struck by running powered equipment during maintenance, cleaning, testing · Fractures

Federal OSHA recorded a severe workplace injury at Oxford Airport Technical Services, 3 Brewster Rd, #A, NEWARK, NEW JERSEY 07114 on — Fractures , affecting the Hand(s), finger(s) unspecified.

An employee was inspecting a conveyor belt for mechanical issues when his right arm became caught between a roller and the belt. The employee was hospitalized with fractures to his right hand.

Hospitalized Hand(s), finger(s) unspecified Conveyors belt, slot, chain

Oxford Airport Technical Services

An employee was deicing snow when they slipped and fell to the ground, resulting in head injuries.

View Oxford Airport Technical Services's full OSHA safety record →

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

CFL USA, LLC

A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

POI Aviation Incorporated

An employee was operating a tug that had been re-tagged due to faulty brakes. As the employee approached the designated parking area, he slowed the tug using the clutch and then exited the tug. He went to stop the tug from colliding with a concrete wall when his right ankle became caught between the tug and a parking stall barrier. He sustained a fractured ankle and was hospitalized.

American Airlines

An employee had just arrived to work and was driving a tug to the gatehouse. The tug ran over chocks while exiting the inbound area, causing the employee to fall to the ground. He was hospitalized with four fractured ribs.

Quantum Aviation Services LLC

An employee was unloading shipping containers from an aircraft when they suffered heat exhaustion and were hospitalized.

Ground Services International

An employee was manually pulling a container from the aft cargo hold of a wide-body jetliner. Their right little finger got pinned between the container and the edge of the cargo door. The employee's finger was partially amputated.

Worldwide Flight Services

An employee was offloading an airplane flight. After driving a transporter car to place a pallet on a static rack, he got off the transporter to apply the lock and secure the pallet on the rack. The pallet began to roll off the rack and pinned the employee against the transporter. He suffered a broken right leg.

JERSEY CITY MEDICAL CENTER

An employee tripped over a stool and fell on the floor, resulting in a left displaced mid-cervical femoral neck fracture.

APM TERMINALS PORT ELIZABETH

An employee was installing fence posts when they stepped into a recently dug hole that was not visible due to rainfall. The employee's leg was fractured.

Allied Waste Systems Inc

An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.

Fitness International, LLC

An employee was inspecting a breaker box and turning on/off a circuit breaker when he was electrocuted.

Bristol Myers Squibb