105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Victaulic

Struck by running powered equipment unspecified · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at Victaulic, 4901 Kesslersville Road, EASTON, PENNSYLVANIA 18044 on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..

An employee was setting up a new job on a sand core machine and testing the blow position when the fixed flag came around and contacted their right index finger resulting in a partial amputation.

Hospitalized Amputation Other finger(s) n.e.c. Extruding, injecting, forming, molding machinery unspecified

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

TABER EXTRUSIONS, LLC

An employee's left arm was caught in the fingers or jaws of the head stretcher machine, resulting in a laceration. The employee was hospitalized.

American Flowform and Machining, LLC

Two employees were setting up a mandrel in the spindle of a machine. The mandrel was side-shifted while an employee's hand was on the mast of a powered industrial truck. The employee suffered crushing injuries that resulted in amputations to the middle and ring fingertips.

Omya Inc.

An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.

Benton Foundry, Inc.

An employee was realigning two halves of a core box on a core-making machine. Pneumatic pressure released, causing the core box to close on the employee's right thumb. The thumb tip was amputated between the nail and the knuckle.

American Cast Iron Pipe Company

An employee was performing maintenance/electrical work inside a substation, and used a ladder to access the top of a panel box. The employee fell 8-9 feet from the top of the panel box to the ground. The employee was hospitalized with fractures to their ribs and a shoulder injury.

NIBCO INC.

An employee's hand was caught in a pinch point in the area of a conveyor for a flask running out of a foundry molding machine. The employee's ring finger was crushed and partially amputated at the base.

American Castings, LLC

An employee noticed a block was out of place under the weighted mold frame. The employee used another block to push the block out and replace it. When the block came out, the frame came down on his right ring and little fingers. The employee sustained a fracture and partial amputation to the ring fingertip.

OSCO Industries Inc.

An employee was using a fork truck to move a tub containing molten iron that had been drained from the cupula. The tub tipped over and the molten metal came in contact with water. This caused the molten iron to splash back and burn the employee's upper torso.

Main Line Clinical Labs

An employee was closing a door when the door closed on their right index finger, resulting in a fingertip amputation.

Ardent Mills

An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.

Zimmerman & Herr

An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.

McAneny Brothers, Inc.

An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.

Metz Culinary Management LLC

An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.