105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

Seaport Fabrication Incorporated

Struck by running powered equipment n.e.c. · Amputations involving bone loss

Federal OSHA recorded a severe workplace injury at Seaport Fabrication Incorporated, 270 N Jungle Road, GENEVA, FLORIDA 32732 on — Amputations involving bone loss, affecting the Other finger(s) n.e.c..

Watch Seaport Fabrication Incorporated — free Get an email when a new federal OSHA severe-injury report for Seaport Fabrication Incorporated is published. One employer, no account, unsubscribe in one click.

An employee was using a table saw to cut a 2-by-4 wood plank into a 1-inch piece when they sustained the amputation of two fingers and were hospitalized.

Hospitalized Amputation Other finger(s) n.e.c. Stationary saws table

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Burke Builders Inc

An employee was cutting cabinet trim using a table saw when four fingers on his left hand were severed, resulting in hospitalization and amputation.

LMMM Houston #80, LTD.

An employee was using a meat saw to slice pork when the blade amputated their right little fingertip.

Electric Boat Corporation

An employee was struck by a plasma cutter and suffered a broken left tibia and fibula. The employee was hospitalized.

General Thermodynamics, Inc.

An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.

General Polymeric Corporation

An employee was monitoring a rotary press when his left hand became caught in the machinery. The employee's left middle finger was amputated at the distal interphalangeal joint.

MCM Plastics, Inc.

An employee was sweeping in an area with powdered PVC on the floor and began having difficulty breathing and coughing up blood, The employee was hospitalized for inhalation of PVC.

Lawter Inc.

An employee was working on a pastillator machine, which processes resin-based materials into solid pastilles. His right hand became caught between the feed roller (operating at approximately 350 F) and the cooling belt. The employee s glove and shirt sleeve adhered to his arm due to the heat. The employee sustained third-degree burns to his right hand and forearm, requiring hospitalization and surgery.

AdvanSix, Inc.

An employee was troubleshooting a leak on a low pressure (less than 50 PSI) condensate line in the oxidation area of the plant. He was working to remove insulation around a valve when either the valve or the line failed, and hot condensate contacted his right arm, right abdomen area, and the front of both legs, resulting in second- and third-degree burns.

Rochling Machined Plastics

An employee was replacing a fan on a cooling unit. As he went to adjust a pump, the unit caught his right hand and the fan blades severely lacerated his index finger. He underwent a medical amputation to the finger.

DRIFTWOOD NURSERY & LANDSCAPING, INC

An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.

Hobby Lobby Stores, Inc.

An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

Sugar Cane Growers Cooperative of Florida

An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.

Air-flo/Erwood Heating & Air Conditioning

An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.