Federal OSHA recorded a severe workplace injury
at Tyson Poultry, Inc., 402 W Olrich St., ROGERS, ARKANSAS 72756
on — Fractures , affecting the Multiple body parts unspecified.
Final narrative
A maintenance technician was changing a wheel on an electric pallet jack. When the employee went to reposition one of the stands supporting the jack, the jack began to lean to one side and fell. The top of the jack struck the employee on the back, resulting in multiple fractures. The employee was hospitalized, requiring hip surgery.
Hospitalized Multiple body parts unspecified Pallet jack riding
On September 25, 2025, an employee was exiting a yard truck. They slipped and fell approximately 3 feet from the top tread of the steps to the concrete below. The employee sustained a fractured left hip.
An employee was moving a cardboard tote of product using an electric pallet jack. After he turned a corner, he came in contact with a round metal bracket that holds a trash bag mounted to a pole. The pallet jack continued forward and his right hand got caught between the pole and the handle of the jack, resulting in an open fracture and crush injury to his thumb that required hospitalization and surgery.
An employee was removing product from a leg quarter saw with a hook when the hook became jammed. As he was getting the hook free, his right hand came into contact with the saw, which partially amputated his middle finger.
An employee was standing at a workstation, preparing to hang poultry. The employee reached to close a manual air damper for an air vent, which caught their left middle finger as it closed. The employee suffered an amputation to the fingertip.
An employee was waiting for test product to come out of a freezer. While the employee was lowering the basket used to catch the test product, their left little finger was caught between the basket and the side shield on the freezer slide chute, resulting in an amputation to the fingertip.
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was attempting to lift a steel beam from a horizontal, stacked position to a vertical position using a crane. They had placed two hooks on the east side of the beam on the flange. As the employee was hoisting the crane, the beam began to shift and pulled the employee forward onto the stack. When the material shifted, the hooks released and the material fell, pinning the employee between the two beams. The employee was hospitalized with soft tissue contusions on their proximal right thigh and interior left thigh.
An employee was moving a tensile strength test device with a dolly. The device fell from the dolly onto the employee's right leg, causing a compound fracture.
An employee was performing maintenance under a kettle. When he removed a tri-clamp on a transfer line, the hot fat and broth material in the kettle poured out onto his arm. The employee was hospitalized with burns.
An employee was walking on top of boiler to close a valve. The employee fell off the boiler and landed on the floor, sustaining fractured ribs. The employee was hospitalized.
An employee was inspecting a pipe in the rice cooking area near an oven. While checking for a clog, the fingers of their right hand were caught in an airlock at the base of the pipe. All the fingers were amputated except the thumb. The employee was hospitalized.
An employee was operating an ironworker (steel punching/shearing) machine. A piece of the tooling broke off and struck the employee's neck; a fragment was lodged in his neck. The employee was hospitalized and required surgery.
On October 25, 2025, an employee was stringing up a new reel of tire tread on a machine. The employee pulled a 6-inch tail and proceeded to spool up the liner. As the machine was jogged to begin the liner wrapping process, the liner caught the employee's glove and pulled their right arm into the liner, causing a fracture to the arm.
An employee was doing a cable change on top of an electric overhead traveling (EOT) crane. They were positioned between the cable drum and the drive shaft. While rotating the cable drum, the employee reached for the new cable that was to be installed. The grease fitting on the drive shaft caught their fall harness and pulled them underneath the drive shaft. The employee was pinned between the drive shaft and two pieces of angle steel, resulting in a fracture to their left hip.
On October 5, 2025, an employee was pulling a pressure washer hose when it it disconnected from the cooker. The employee was struck by jets of high-pressure water, resulting in lacerations to their left thigh requiring surgery. The employee was hospitalized.