Cargill Meat Solutions

Struck by running powered equipment during maintenance, cleaning, testing · Amputations involving bone loss

Federal OSHA recorded a severe workplace injury at Cargill Meat Solutions, 1505 E. Burlington Ave., FORT MORGAN, COLORADO 80701 on — Amputations involving bone loss, affecting the Finger or thumb tip(s), nail(s).

An employee was in the basement when he observed animal blood dripping from a small hole in the auger trough. The employee went to plug the hole with a small piece of fat. As the employee pushed the fat into the hole, the auger flight caught his fingertip, resulting in amputation between the nailbed and first knuckle.

Amputation Finger or thumb tip(s), nail(s) Butchering machinery

Cargill Meat Solutions

An employee was operating a band saw and sustained a partial amputation to their right index fingertip.

Cargill Meat Solutions

An employee was removing scraps of meat from underneath a barrel dumper when she was struck by the barrel dumper, resulting in pelvic fractures.

CARGILL MEAT SOLUTIONS

An employee was pushing a piece table when it struck a machine. The employee's finger was pinched and partially amputated between the table and machine.

Cargill Meat Solutions

An employee was driving a forklift when it collided with another forklift. The employee's middle finger was pinched between the two forklifts and partially amputated.

Cargill Meat Solutions

An employee was positioning a shackle onto a transition wheel to hang carcasses on the incline chain. The shackle twisted and the employee's right index finger was pinched between the shackle shaft and rail guide plate. The employee sustained a partial amputation to the fingertip and a distal tuft fracture to the finger.

View Cargill Meat Solutions's full OSHA safety record →

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

CFL USA, LLC

A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Tyson Fresh Meats, Inc.

An employee was scraping dried glue from the top lid of a hot glue pot. His left hand slipped and came into contact with the hot glue. He then suffered burns to his hands and fingers as he tried to remove the glue. He was hospitalized.

Intermountain Packing, LLC

An employee was in a scissor lift approximately 20 feet above the ground to place a plastic tarp on a catwalk in order to catch condensation. They positioned the lift opposite the work area and stepped out of the scissor lift onto an I-beam. The employee fell from the I-beam to the ground. The employee was hospitalized with a skull fracture on the right side of their head and injuries to the chest and both eyes.

Cargill Meat Solutions Corporation

A maintenance employee was called to look at a pallet conveyor machine where a chain had fallen off a sprocket wheel. When the employee grabbed the loose chain, a light sensor caused the machine to restart. This created a pinch point between the chain and sprocket that caught the employee's left little finger. The finger was surgically amputated at the second knuckle.

JBS Souderton, Inc.

The injured employee was standing by one of the stationary computers along the wall. There was a half-pallet located approximately 3 feet behind the employee that consisted of 12-pound boxes stacked six boxes high. A forklift was transporting a pallet that came in contact with the stationary pallet behind the injured employee, causing four boxes to fall and contact their legs. The injured employee was hospitalized with leg injuries.

Smithfield Foods

An employee was using a box strapping machine to place straps on boxes when his right middle finger was caught in the machine, resulting in an open fracture to the distal phalanx.

ABC Supply Company

An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.

Burke Builders Inc

An employee was cutting cabinet trim using a table saw when four fingers on his left hand were severed, resulting in hospitalization and amputation.

Circle Graphics, Inc.

An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.

FLATIRON CONSTRUCTION CORP.

A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.

Takkion OPS Management

An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.