CB Manufacturing Company INC

Struck by running powered equipment during maintenance, cleaning, testing · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at CB Manufacturing Company INC, 2200 NEW BRUNSWICK AVE., PISCATAWAY, NEW JERSEY 08854 on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).

An employee was conducting maintenance on the bag in box (BIB) palletizer machine when the motor chain jumped, pulling his right index finger into the chain drive attached to the motor and causing a fingertip amputation.

Amputation Finger or thumb tip(s), nail(s) Stacking machinery

CB Manufacturing Company, Inc.

An employee was replenishing product in a warehouse aisle. They collapsed and fell onto their back, striking their head on the concrete and suffering a laceration to the back of their head and injuries requiring hospitalization and brain surgery.

CB Manufacturing Company, Inc.

An employee was realigning a cap hopper on top of its platform when their right middle finger was pinched, resulting in a fingertip amputation.

CB Manufacturing Company, Inc.

An employee was operating a riding pallet jack when it struck a charging station. The employee's leg was caught between the rack of the charging station and the pallet jack and fractured.

CB Manufacturing Company, Inc.

An employee was performing maintenance on a chain drive for a conveyer belt motor. When the conveyor belt turned on, the chain drive contacted their left middle finger, resulting in a fingertip amputation. The conveyor was not locked out at the time of the incident.

CB Manufacturing Company, Inc.

A maintenance mechanic was working on a valve on a clean-in-place system in the syrup room when hot water released, causing the employee to sustain first and second-degree burns to the right side of back, arm, and legs.

View CB Manufacturing Company INC's full OSHA safety record →

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

CFL USA, LLC

A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

NIAGARA BOTTLING LLC

A mechanic was performing a modular overhaul on a blower. While removing magnetic rods for the stretch rod, the employee was placing the second rod on the blower platform. The rods were magnetically attracted to one another, and the employee's left third and fourth fingers were pinched between them. She was hospitalized and sustained a partial amputation.

Niagara Bottling, LLC

An employee was clearing a piece of tape from the tape dispenser when their hand contacted the cutting implement on the dispenser. The employee suffered the amputation of their right index finger.

Blue Triton Brands

An employee was troubleshooting a bottle machine because the nozzle was stuck in the up position. The employee went to check for pre-blow air and the nozzle dropped back down to its starting position, catching his right index fingertip against the mold base. The employee sustained a fingertip amputation to the first digit.

Eldorado Artesian Springs, Inc

An employee was attempting to clear a bottle jam when they were pinned to the wall by the arm of a robotic bottle stacker. The employee sustained an abdominal injury that required hospitalization. The machine was not guarded at the time.

BlueTriton Brands, Inc.

An employee was tensioning the chain of a packing machine. The employee's right index finger was caught in the chain sprocket, and the fingertip was amputated.

JERSEY CITY MEDICAL CENTER

An employee tripped over a stool and fell on the floor, resulting in a left displaced mid-cervical femoral neck fracture.

APM TERMINALS PORT ELIZABETH

An employee was installing fence posts when they stepped into a recently dug hole that was not visible due to rainfall. The employee's leg was fractured.

Allied Waste Systems Inc

An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.

Fitness International, LLC

An employee was inspecting a breaker box and turning on/off a circuit breaker when he was electrocuted.

Bristol Myers Squibb

An employee was walking on the sidewalk. When they stepped off the curb, they fell to the ground, resulting in fractures to their tibia, fibula, and a metatarsal.