105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

New England Wire Products, Inc

Struck by running powered equipment during maintenance, cleaning, testing · Amputations, avulsions, enucleations unspecified

Federal OSHA recorded a severe workplace injury at New England Wire Products, Inc, 49 Depot Street, KINGFIELD, MAINE 04947 on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).

On June 3, 2025, an employee was operating a drill press. He wiped oil from the top of the tubing he was drilling, and the drill bit caught his glove and pulled his finger into the drill. He suffered an amputation to the left index fingertip.

Amputation Finger or thumb tip(s), nail(s) Stationary drills, milling machinery

New England Wire Products Inc.

An employee was operating a shear to cut metal parts when two of their fingers contacted the blade. This resulted in amputation of the left middle and index fingertips.

New England Wire Products, Inc

An employee was working with a drill press when his right glove was caught and pulled into the drill bit. The employee's little fingertip was partially amputated.

New England Wire Products Inc.

An employee was operating a brake press and making the final bend on a steel part. Her right middle finger got caught between the part and the top punch as it bent the part upward. The employee sustained a crush injury resulting in amputation of the fingertip.

New England Wire Products, Inc

An employee's finger was caught and amputated in a CNC machine while in setup mode.

New England Wire Products, Inc

An employee was bending a piece of metal tubing on a horizontal tube bender. The employee's thumb was caught between the tube and the die, and the tip of the thumb was amputated.

View New England Wire Products, Inc's full OSHA safety record →

Envelope Seal Insulation, Inc

An employee was inspecting a generator whose radiator was leaking. He slipped, and a fan blade in the generator amputated his thumb and index finger.

CFL USA, LLC

A temporary employee turned off a planer machine, opened the housing, and began clearing a jam. The machine's spinning blade caught his right hand and degloved the index finger.

Bull Moose Tube

An employee was using a tool to remove a rag from a roll on the tube mill. The roll pulled the tool and the employee's right hand into the roll, resulting in a partial amputation of the little finger and a fracture to the index finger.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Sargento Foods Inc

A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.

Encore Wire Corporation

An employee was loading an empty reel on the west reel take-up when they noticed that the wire lying on the east reel take-up had over-accumulated on one side of the reel, making it uneven. The employee stopped the east take-up machine and released tension on the wire to correct the lay. As the employee engaged a mechanical rotation function to take up the wire slack, their right little finger was crushed between two separate wire strands on the reel under tension, resulting in a fingertip amputation. The machine was guarded at the time of the incident.

Mueller Copper Tube

An employee was operating an overhead crane to transport a bundle of copper tubing. He went to lower the load as he was approaching a rack, but the suspended bundle of tubing suddenly jerked in the other direction. The bundle struck a nearby tool cabinet, and the cabinet tipped over. The employee went to prevent it from falling. However, the cabinet still fell over, striking his right arm and briefly pinning it against another object. The employee suffered a fractured right forearm that required hospitalization.

Hailiang Copper Texas Inc

An employee was working to manually clear copper tubes from the turnover rack due to a faulty sensor. As he used his right hand to remove a finished tube from the turnover rack, another tube pushed through the feed line and struck his gloved right ring fingertip. The sharp edge of the copper tube caused a soft tissue amputation to the bottom side of the fingertip.

Mueller Copper Tube

An employee was cleaning slag from a casting mold at a furnace. The molten copper dropped out of the mold too quickly, reacted with the mold cooling water, and blew out. The molten metal struck his right foot, hand, and torso, causing first-, second-, and third-degree burns.

New England Wire Products, Inc

An employee was working with a drill press when his right glove was caught and pulled into the drill bit. The employee's little fingertip was partially amputated.

HB Fleming, Inc.

A crew was installing drilled micropiles alongside an outdoor covered deck foundation. The injured employee was working the front of the drill when a loose section of casing dropped onto the tip of a rig wrench and pulled the wrench down to an embedded casing. The employee's left little finger was caught between the rig wrench and the embedded casing and was amputated above the top knuckle.

GERRITY INDUSTRIES

Two employees were working to change a tire on a mobile slasher saw. The slasher weighs around 2,000 pounds and is towed. Employee 2 was lifting the saw while the injured employee was placing a block of wood under the frame for support. The slasher then lowered onto the block and the injured employee's left thumb was crushed between the slasher frame and the wood block, leading to an amputation at the first knuckle.

O&P Glass

An employee was using a metal shear when it amputated the tip of his right index finger.

Cives Steel Company New England

An employee was using a crane to move a 44-foot, 3,343-pound I-beam. As the beam was moving west, it straightened out (north to south), beginning to swing south toward the northwest corner of a building. The crane then sent the beam southward, directly toward the corner of the building. The beam caught the tips of the employee's left index, middle, and ring fingers against the building. The last joints of the middle and ring fingers were amputated, and the last joint of the index finger was partially crushed.

Longroad Energy

An employee was standing on a step stool, removing the nuts and bolts from the frame of a solar panel that was being replaced. The employee's cheek made contact with a connector with damaged insulation. The employee was shocked, briefly lost consciousness, and fell to the ground, suffering an injury to the left shoulder.