Rail Terminal Services LLC

Fall to lower level resulting from exposure or contact less than 6 feet · Fractures

Federal OSHA recorded a severe workplace injury at Rail Terminal Services LLC, 4500 Samuel Blvd, MESQUITE, TEXAS 75149 on — Fractures , affecting the Trunk and other upper extremities.

The injured employee loaded a container onto a railcar and then mounted the railcar to put in the locking mechanism for the container. The employee was struck by another container that a crane was loading onto the railcar and fell approximately four feet from the railcar to the concrete ground. The employee sustained fractures to their pelvis, shoulder, and two ribs.

Hospitalized Trunk and other upper extremities Heavy rail vehicles unspecified

The Home Depot USA, Inc.

An employee was unloading freight from a truck when a stack of doors fell over and knocked the employee to the ground. The employee sustained a fractured femur.

Longroad Energy

An employee was standing on a step stool, removing the nuts and bolts from the frame of a solar panel that was being replaced. The employee's cheek made contact with a connector with damaged insulation. The employee was shocked, briefly lost consciousness, and fell to the ground, suffering an injury to the left shoulder.

Stallion Oilfield Construction, LLC

An employee was removing a hot water heater (that was full of water) from a trailer. The glove on his left hand was caught on the pipes of the moving water heater, causing him to lose balance and fall approximately 4 feet from a ladder to the ground below. The employee's lower left leg and hip were fractured.

Cutco Corp.

Employees were upgrading lighting fixtures in the accounting offices. The injured employee was on a ladder working on a ceiling light fixture. He came into contact with the metal grating surrounding the fixture and sustained an electrical shock that caused him to lose balance and fall approximately 3 to 4 feet to the floor. The injured employee sustained a fractured pelvis and a torn rotator cuff.

Electrical Specialists, Inc.

An employee was working in an electrical junction box and was shocked by an energized circuit. The employee fell off a ladder about 3-4 feet to a cement floor, sustaining fractures to his left shoulder and right heel. The employee was hospitalized.

Greenbrier Rail Services

An employee was using his left hand to push an axle down the line on a raised track work area while holding the remaining axle back with his right hand. A finger on his right hand was caught between the rail and the dust guard of the axle, resulting in a fracture and a laceration.

GATX Corporation

An employee was sampling a railcar in a storage yard. After sampling the railcar, the employee was climbing down the railcar ladder when he fell off the top step of the ladder to the ground, resulting in fractures to six ribs, his right arm, and two vertebrae.

Drummac, Inc.

Employees were watering a train at a train platform. One of them went to step over a hose, tripped, and fell to the ground. He suffered a broken knee. The employee was hospitalized for surgery.

Loram Maintenance of Way, Inc.

Employees were performing maintenance operations on a railroad line when the machine experienced a load conveyor motor failure. While clearing the machine to allow for repairs, an employee pinned the left side of the swing conveyor. The operator on the right side then requested a slight bump to the left to align the right side for pinning. Once the swing was in position, the operator went to pin the right side and the chain tensioner failed, resulting in an abrupt release of the swing chain. The chain snapped back and struck the operator s right hand, resulting in a 1-inch laceration and a fractured fifth metacarpal. The employee was hospitalized and required surgery on the hand.

Metro East Industries, Inc.

An employee was removing a power assembly from a locomotive engine using an overhead crane. The power assembly became stuck, and two 1-inch lifting bolts failed as the crane continued to apply lifting pressure. This cause the power assembly to come back down and crush the employee's right hand against the engine housing. He suffered two broken bones in the hand, as well as tissue and ligament damage, and was hospitalized.

T G Meat Center LLC

After cutting a slab of beef short ribs, an employee turned to grab the pieces he had cut and his right hand contacted the saw blade. The employee sustained an amputation to his right index finger.

Professional Flooring Supply

An employee was unloading a carpet pad from a truck when they fell from the truck dock to the concrete below, resulting in five fractured ribs and an injury to their left lung.

EnviroSafe Demil LLC

An employee was inspecting flares processes. The employee received burns to the front side of the body, face and arm from the flares.

Inteplast Group

An employee was removing plastic material from a production line when the machine cycled and amputated his left index, ring, and little fingers.

Regency IHS of Fairwinds Halletsville, LLC

An employee was walking up a walkway to enter a building through the back entrance when she tripped over the lip of the cement ramp. The employee fell and sustained a fractured right hip.