Struck by falling object unspecified · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at S&R Compression, LLC, 4234 S Jackson Ave, TULSA, OKLAHOMA 74107
on — Amputations, avulsions, enucleations unspecified, affecting the Finger or thumb tip(s), nail(s).
Final narrative
A crane had been used to set a steel plate on a steel frame. An employee was trying to remove a clamp from the plate when the plate fell and crushed the tip of his left little finger. The employee sustained a fingertip amputation.
Amputation Finger or thumb tip(s), nail(s) Panels, sheets, plates metal
An employee was walking past a crossover conveyor when a ramp came down and hit them in the back. The employee sustained a broken back vertebra, as well as a concussion, and was hospitalized.
An employee was unloading frameless mirrors from a trailer. When unstrapped, the mirrors fell over onto the employee, who suffered a skull fracture, a brain bleed and blood clot, a broken left ankle, and lacerations.
A temporary employee was rigging secondary steel when the steel joist fell to the ground and struck his lower left leg, resulting in fractures to the tibia and fibula.
Two maintenance employees were dismantling a machine part (steel cylindrical rollers) on the ground. After unbolting a portion, part of the assembly fell approximately 6 inches onto one employee's left little finger. The employee was hospitalized and about 3/4" of their little finger above the top joint was surgically amputated.
An employee was sorting sucker rods. His right hand was caught in the area where the rod hits up against the frame and his index fingertip was amputated just below the nail.
An employee was using a powered miter saw to cut 2x4's. The saw blade hit something inside a board (possibly a hidden nail) and jumped, causing a laceration to the employee's left forearm. The employee was hospitalized with soft tissue and tendon injuries that required surgery.
An employee was operating a scissor lift, raised to a height of about 15 feet, to inspect an overhead crane rail. The crane itself was being moved. Its hook swung into the scissor lift s arms, causing the lift to tip over onto its side, which in turn caused the lift and the employee to fall to the floor. The employee suffered injuries including broken ribs, spinal fractures, scapula fractures, and internal injuries.
A technician was operating a crane hoist to lift/remove a cylinder head from the main engine (port). The load was lifted at an angle, causing the cylinder head to get stuck on the cylinder head studs. When it became free from the studs, the cylinder head swung. It struck the technician and caught them against the cabinet door. This resulted in an amputation of their left index fingertip at the distal knuckle.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.
An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.
An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.