Contact incidents unspecified · Amputations involving bone loss
At a glance
Federal OSHA recorded a severe workplace injury
at SGS Contracting Services, Inc., 200 SE 16th Ave., GAINESVILLE, FLORIDA 32601
on — Amputations involving bone loss, affecting the Other finger(s) n.e.c..
Final narrative
An employee was working to install a pipe coupling on a section of steel pipe. The pipe became dislodged from its temporary support structure. As the employee went to gain control of the pipe, his right little finger was caught and amputated near the knuckle in a pinch point created by the pipe.
Amputation Other finger(s) n.e.c. Pipes, tubes metal
A crew was installing drilled micropiles alongside an outdoor covered deck foundation. The injured employee was working the front of the drill when a loose section of casing dropped onto the tip of a rig wrench and pulled the wrench down to an embedded casing. The employee's left little finger was caught between the rig wrench and the embedded casing and was amputated above the top knuckle.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.
An employee was installing a hydraulic extension cylinder in a tow truck when their leg was caught between the cylinder and the truck frame. The employee was hospitalized with a broken tibia, which required surgery.
An employee was sorting sucker rods. His right hand was caught in the area where the rod hits up against the frame and his index fingertip was amputated just below the nail.
More severe injuries in this industry (NAICS 541330)
An employee was working to free a load by grabbing and shaking the live side of a tugger line. Once the load became free and progressed upward, the employee's hand was caught and pulled into a snatch block. The employee's right thumb was broken and lacerated. The employee was hospitalized and required a surgical amputation.
An employee was operating a drill rig when when their hand got caught between a 1/4-inch steel cable and a drill rod, resulting in the amputation of four fingers.
An employee was overseeing the operation of a rope being respooled onto the drum of a wire winding machine. He went to remove a piece of wooden reel from the rope. His glove got snagged and his right hand was pulled into the roller, pinching his fingers between the machine's roller and the rope. The middle and index fingers were crushed.
An employee was visiting a patient's home to fit them with a wearable cardiac defibrillator. As he was walking from the front door to his car, a large dog broke free from a chain and attacked him. He was bitten on the forearm and fell. The patient was then able to restrain the dog. The employee was hospitalized with severe dog bites and required surgery.
An employee tripped over a junior I-beam about 4 feet long and 6 inches tall that was installed for circulating water valves and fell to the ground, resulting in a broken right-side rib.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.