Federal OSHA recorded a severe workplace injury
at Pam Air-Services, Inc, Group, 825 5th Ave, NEW YORK, NEW YORK 10060
on — Fractures , affecting the Rib(s), oblique area.
Final narrative
An employee was working in the ceiling on an HVAC unit. While switching out a part, an evaporator coil struck the employee in the chest, leading to multiple fractured ribs on their right side. The employee was hospitalized.
Hospitalized Rib(s), oblique area Machine hydraulics and pressurized components unspecified
A crew was installing drilled micropiles alongside an outdoor covered deck foundation. The injured employee was working the front of the drill when a loose section of casing dropped onto the tip of a rig wrench and pulled the wrench down to an embedded casing. The employee's left little finger was caught between the rig wrench and the embedded casing and was amputated above the top knuckle.
An employee was checking a pole-type transformer tank for leaks. A hydraulic clamping device was lowered onto his right thumb and crushed it against the sharp edge of the bottom of the tank. He suffered a partial transphalangeal amputation to the thumb.
An employee had been cleaning the work area. While lifting a saw, the employee's index finger was lacerated by the saw blade. A tendon was cut and required surgery.
An employee was installing a hydraulic extension cylinder in a tow truck when their leg was caught between the cylinder and the truck frame. The employee was hospitalized with a broken tibia, which required surgery.
An employee was sorting sucker rods. His right hand was caught in the area where the rod hits up against the frame and his index fingertip was amputated just below the nail.
More severe injuries in this industry (NAICS 238220)
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.
An employee was closing the side cargo door to a company van. The tip of his finger got caught between the door and the door jamb, resulting in a partial amputation.
While working at a customer's residence, an employee was cutting tape with a box cutter to wrap insulation for a piece of pipe. The box cutter struck a hardened object within the wall causing it to bounce back and puncture the employee's right eye. The employee was hospitalized.
An employee was assembling a baker type scaffold. He was beginning to transverse down the scaffold, approximately six feet off the ground, when the scaffold tipped over and he fell. The employee was hospitalized with a fractured femur.
An employee was trimming out sprinklers on the exterior of a building when he fell off an extension ladder. He landed on the ground and sustained fractures to his nose and arm.
An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.
An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.
An employee was directing trucks as they entered and left a highway work zone. A vehicle struck them, resulting in multiple fractures and other injuries. The employee was hospitalized.