ERIE, PA —
OSHA Inspection: ERIE PLATING COMPANY
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of ERIE PLATING COMPANY in 656 W. 12TH STREET, ERIE, PA 16501 (NAICS 332813). OSHA activity number 338914617.
Where did this inspection happen?
- Establishment
- ERIE PLATING COMPANY
- Site address
- 656 W. 12TH STREET
- City
- ERIE
- State
- PA
- ZIP
- 16501
- Mailing
- 656 WEST 12TH STREET, ERIE, PA 16501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 50
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.151(c): The employer did not ensure that where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body was provided within the work area for immediate emergency use. a.) Deptartment 13, Nickel/Chrome plating area - On or about February 22, 2013, and at times prior thereto, the emergency eyewash in the immediate area was not operable. Company employees in Department 13 worked with and around corrosive chemicals including, but not limited to, sulfuric acid, sodium copper cyanide and sodium hydroxide.
Recent events (2)
- — I (S) $1000
- — Z (S) $2380
1910.1200 F05 I
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a.) Department 13, Nickel/Chrome plating area - On or about February 11, 2013, an employee adding chemicals to the plating tanks utilized 2 white 5-gallon buckets, one contained sulfuric acid and the other contained caustic liquids, that were not labeled to identify the product contained therein. Sticky notes were utilized on the bucket lids to identify the chemical within. After the lids were removed, the employee mistakenly added sulfuric acid to the copper cyanide tank causing a chemical reaction that splashed corrosive chemicals out of the tank and onto the employee, resulting in second degree chemical burns.
Recent events (2)
- — I (S) $3000
- — Z (S) $4200
1910.1200 F05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a.) Department 13, Nickel/Chrome plating area - On or about February 11, 2013, an employee adding chemicals to the plating tanks utilized 2 white 5-gallon buckets, one contained sulfuric acid and the other contained caustic liquids, that were not labeled to identify the hazard warnings of the chemicals contained therein. Sticky notes were utilized on the bucket lids to identify the chemical within. After the lids were removed, the employee mistakenly added sulfuric acid to the copper cyanide tank causing a chemical reaction that splashed corrosive chemicals out of the tank and onto the employee, resulting in second degree chemical burns.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ERIE PLATING COMPANY
ERIE, PA—2022-08-16 00:00:00
ERIE PLATING COMPANY
ERIE, PA—2022-05-12 00:00:00
ERIE PLATING COMPANY
ERIE, PA—2019-05-07 00:00:00
ERIE PLATING COMPANY
ERIE, PA—2017-04-27 00:00:00
ERIE PLATING COMPANY
ERIE, PA—2017-04-27 00:00:00
ERIE PLATING COMPANY
View ERIE PLATING COMPANY's full OSHA safety record →
More inspections in this industry (NAICS 332813)
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
WARSAW, IN—2026-07-08
SURFACE ENHANCEMENTS
KENT, WA—2026-07-06
WA317991930 - HYTEK FINISHES CO
PHOENIX, AZ—2026-06-24
CPX2026XTP177X0010 - FRONTIER GROUP, INC.
MELROSE PARK, IL—2026-06-24
NATIONAL PLATING SOLUTIONS LLC DBA SOMERVILLE PLATING
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338914617.