MILWAUKEE, WI —
OSHA Inspection: SIC LAZARO U.S. INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SIC LAZARO U.S. INC. in 7044 N. TEUTONIA AVE., MILWAUKEE, WI 53209 (NAICS 332420). OSHA activity number 339081804.
Where did this inspection happen?
- Establishment
- SIC LAZARO U.S. INC.
- Site address
- 7044 N. TEUTONIA AVE.
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53209
- Mailing
- 7044 N. TEUTONIA AVE., MILWAUKEE, WI 53209
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 29
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.146 C01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: (a) The employer inadequately evaluated the Quanzhou Hengxing Industry Machinery Co., LTD concrete mixer exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) While cleaning the Quanzhou Hengxing Industry Machinery Co., LTD concrete mixer, all energy sources were not properly de-energized exposing employees to accidental / inadvertent restart of equipment. (b) While cleaning the Quanzhou Hengxing Industry Machinery Co., LTD concrete mixer, energy isolating devices were not properly utilized / placed exposing employees to accidental / inadvertent restart of equipment.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.147 F03 II D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: (a) Each employee did not apply the lock out device prior to commencing cleaning operations on the Quanzhou Hengxing Industry Machinery Co., LTD mixer exposing employees to accidental/inadvertent startup of equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: (a) The employer did not certify periodic inspections of the energy control procedures and authorized employees had been conducted to ensure the skills, knowledge, and content were accurate.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: (a) The electrical conduit leading to the motor on the Quanzhou Hengxing Industry Machinery Co., LTD concrete mixer was separated from the end connector, exposing the wiring to damage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SIC LAZARO U.S. INC.
MILWAUKEE, WI—2023-04-05 00:00:00
SIC LAZARO U.S. INC.
MILWAUKEE, WI—2021-07-15 00:00:00
SIC LAZARO U.S. INC.
MILWAUKEE, WI—2015-03-06 00:00:00
SIC LAZARO U.S. INC.
MILWAUKEE, WI—2013-12-13 00:00:00
SIC LAZARO U.S. INC.
MILWAUKEE, WI—2013-12-13 00:00:00
SIC LAZARO U.S. INC.
View SIC LAZARO U.S. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332420)
WRENS, GA—2026-07-08
LEWIS STEEL WORKS, INC.
THEODORE, AL—2026-06-25
CHART INDUSTRIES, INC.
BALL GROUND, GA—2026-06-09
CHART INDUSTRIES
ROLAND, OK—2026-06-02
PITTSBURG TANK & TOWER
ODESSA, TX—2026-05-26
P2 CONSTRUCTION INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339081804.