Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: C & S CANOPY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C & S CANOPY, INC. in 101 SHADETREE DR., CLANTON, AL 35045 (NAICS 236220). OSHA activity number 339309064.

Watch C & S Canopy, INC. — free Get an email when a new federal OSHA severe-injury report for C & S Canopy, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
C & S CANOPY, INC.
Site address
101 SHADETREE DR.
City
CLANTON
State
AL
ZIP
35045
Mailing
101 SHADETREE DR., CLANTON, AL 35045
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
27
Ownership type
A

4 citations on file for this inspection.

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1517.00 · Current $1517.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) Welding shop: On or about August 14, 2013 and times prior the employer exposed employees to struck-by hazard by not ensuring the work rest on the bench grinder was properly adjusted to within 1/8 inch of the grinding wheel.
Recent events (1)
  • — Z (S) $1517

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) Welding shop: On or about August 14, 2013 and times prior the employer exposed employees to struck-by hazard by not ensuring the tongue guard on the bench grinder was properly adjusted to within 1/4 inch of the grinding wheel.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2023.00 · Current $2023.00
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.   a) Welding shop:  On or about August 14, 2013 and times prior the employer did not ensure that all electrical blanks for circuit breakers on the panel box were effectively closed which exposed employees to  electrical hazards.
Recent events (1)
  • — Z (S) $2023

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Welding shop: On or about August 14, 2013 and times prior the employer exposed employees to electrical or fire hazards by allowing temporary wiring (extension cords) to be used as permanent wiring to provide power to bench grinder and flood light.