1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TOWER INTERNATIONAL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TOWER INTERNATIONAL in 440 CHURCH ROAD, MADISON, MS 39110 (NAICS 336399). OSHA activity number 340171107.

Watch Tower International — free Get an email when a new federal OSHA severe-injury report for Tower International is published. One employer, no account, unsubscribe in one click.
Establishment
TOWER INTERNATIONAL
Site address
440 CHURCH ROAD
City
MADISON
State
MS
ZIP
39110
Mailing
440 CHURCH ROAD, MADISON, MS 39110
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
213
Ownership type
A

5 citations on file for this inspection.

1910.23 A08

Other-than-serious 1 instance 19 exposed
Issued
Penalty
Initial $2550.00 · Current $0.00 Reduced
29 CFR 1910.23(a)(8): Floor hole(s), into which persons could accidentally walk, were not guarded by standard railings with standard toeboards on all exposed sides or by floor hole covers of standard strength and construction:      (a) Main Line Mezzanine at Op 870 - On or about January 7, 2015, there was a gap in the flooring measuring 2 inches by 29 1/2 inches into which employees could accidentally walk.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2550

1910.178 P01

Serious Gravity 5 1 instance 12 exposed
Issued
Penalty
Initial $2550.00 · Current $2500.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) with defect(s) or in any way unsafe had not been withdrawn from service until restored to safe operating condition(s):    (a) Shipping Department - On or about January 7, 2015, forklifts in need of repairs including inoperable backup alarms, inoperable headlights and unmounted fire extinguishers, had not been removed from service.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $2550

1910.303 G01

Other-than-serious 2 instances 19 exposed
Issued
Penalty
Initial $1913.00 · Current $1913.00
29 CFR 1910.303(g)(1):  Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.    (a)  Maintenance Shop - On or about January 7, 2015, sufficient access and working space was not provided and maintained about electric equipment as required.
Recent events (2)
  • — I (O) $1913
  • — Z (S) $1913

1910.303 G02 I

Serious Gravity 5 1 instance 19 exposed
Issued
Penalty
Initial $2550.00 · Current $1800.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:    (a) Near QW Op 808 - On or about January 7, 2015, the cover was missing from the electrical panel underneath the aisle side lift table.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2550

1910.305 B03 II

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $1913.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(3)(ii): Boxes were not closed by suitable covers securely fastened in place.      (a)  CMM Room - On or about January 7, 2015, a junction box was not securely fastened to the wall.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1913

View TOWER INTERNATIONAL's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340171107.