OSHA Inspection: PAVLOF FISHERIES LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PAVLOF FISHERIES LLC in M/V PAVLOF DELTA WESTERN DOCK, DUTCH HARBOR, AK 99692 (NAICS 112511). OSHA activity number 340418482.

Watch Pavlof Fisheries LLC — free Get an email when a new federal OSHA severe-injury report for Pavlof Fisheries LLC is published. One employer, no account, unsubscribe in one click.
Site address
M/V PAVLOF DELTA WESTERN DOCK
City
DUTCH HARBOR
State
AK
ZIP
99692
Mailing
3900 RAILWAY AVENUE, EVERETT, WA 98201
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112511
Employees
19
Ownership type
A

9 citations on file for this inspection.

1910.95 G06

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :  Engine Space:  On or about 2/7/2015, and times prior thereto, employees working in the engine space with generators running were exposed to noise at 105 dB(A) for 6 hours.  This exposed employees to hearing loss hazards.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.212 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1666.00 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:  (a)  Bow compressor room: On or about February 7, 2015 and times prior thereto, a fan at two feet off the floor was not guarded properly to protect from inadvertent contact with the blades.  This exposed employees to laceration/amputation hazard to their hands
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

1910.253 B04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1666.00 Reduced
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire;   (a)  Forward factory:  On or about February 7, 2015 and times prior thereto, two oxygen and one acetylene bottles were stored together.  This exposed employees to increased smoke/fire hazard if the bottles vented or were engulfed in a fire.
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

1910.1200 E01

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a)  Vessel:  On or about February 7, 2015 and times prior thereto, the employer did not have a written hazard communication program.  This exposed employees to not knowing the safety and health requirements for the chemical hazards being used.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1915.56 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1666.00 Reduced
29 CFR 1915.56(b)(4): Welding cable in poor condition was used.  (a)  Work room:  On or about February 7, 2015 and times prior thereto, welding cable cut to the conductor 3 feet from the holder was used by employees.  This exposed employees to shock/burn hazard from inadvertent contact with the conductor.
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

1915.159 C01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3430.00 Reduced
29 CFR 1915.159(c)(1)(i): The attachment point of a body harness was not located in the center of the wearer's back near the shoulder level, nor above the wearer's head.  (a)  Deck:  On or about November 7, 2015 and times prior thereto, an employee would tie a knot to the side attach point of the harness.  The connection was not in the proper place and using a knot in a rope is not an acceptable way to attach.  This exposed employee to broken bones or death if they fell with the connection in this manner.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1915.159 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1915.159(c)(3): Ropes, belts, harnesses and lanyards were not compatible with their hardware.  (a)  Deck:  On or about February 7, 2015 and times prior thereto, an employee was using a natural rope with a non locking connector.  Neither of these items are part of a fall protection system.  This exposed the employee to broken bones or death if they were to fall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.159 D

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1915.159(d): Affected employees were not trained so that they could demonstrate the proper use, inspection, and storage of their fall arrest equipment.  (a)  Deck:  On or about February 7, 2015 and times prior thereto, an employee was not properly trained to use fall protection.  Employee was incorrectly using a rope lanyard, connector and was attaching it to the side of the harness.  The lack of proper training exposed employee to broken bones or death from not using equipment in the proper manner.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  Vessel:  On or about February 7, 2012 and times prior thereto, employees wore full face respirators when there were ammonia leaks and the vessel had no program in place for safe use of respirators.  This exposed employees chemical hazard from not having a respirator fit properly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PAVLOF FISHERIES LLC's full OSHA safety record →