Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BIERY CHEESE CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BIERY CHEESE CO. in 6544 PARIS AVE., LOUISVILLE, OH 44641 (NAICS 311513). OSHA activity number 340571512.

Watch Biery Cheese CO. — free Get an email when a new federal OSHA severe-injury report for Biery Cheese CO. is published. One employer, no account, unsubscribe in one click.
Establishment
BIERY CHEESE CO.
Site address
6544 PARIS AVE.
City
LOUISVILLE
State
OH
ZIP
44641
Mailing
6544 PARIS AVE., LOUISVILLE, OH 44641
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
400
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Deleted Serious Gravity 10 2 instances 30 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about April 21, 2015, the employer failed to ensure the ingoing nip points on the Line 6 and 7 conveyors were properly guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.335 A01 I

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $5600.00 Reduced

Hazardous substances 8870

29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    On or about April 20, 2015, the employer failed to ensure employees performing electrical work, to include voltage testing up to 3 phase 480VAC, were protected against contact by utilizing voltage rated gloves.
Recent events (2)
  • — I (S) $5600
  • — Z (S) $7000

1910.335 A01 V

Deleted Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 8870

29 CFR 1910.335(a)(1)(v): Employees did not wear protective equipment for the eyes or face wherever there is danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion:  On or about April 21, 2015, the employer failed to ensure employees performing electrical work, to include voltage testing, were protected against an arc flash by wearing face protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View BIERY CHEESE CO.'s full OSHA safety record →