Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BIERY CHEESE CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BIERY CHEESE CO. in 6544 PARIS AVE, LOUISVILLE, OH 44641 (NAICS 311513). OSHA activity number 344537733.

Watch Biery Cheese CO. — free Get an email when a new federal OSHA severe-injury report for Biery Cheese CO. is published. One employer, no account, unsubscribe in one click.
Establishment
BIERY CHEESE CO.
Site address
6544 PARIS AVE
City
LOUISVILLE
State
OH
ZIP
44641
Mailing
6544 PARIS AVE, LOUISVILLE, OH 44641
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
420
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $9639.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.    On or about December 23, 2019, the employer did not ensure an employee utilized the developed and documented procedures for the control of hazardous energy while adjusting the line #15 Weber cheese slicer machine.
Recent events (3)
  • — F (S) $0
  • — C (S) $9639
  • — Z (S) $9639

1910.147 D

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:   On or about December 23, 2019, the employer did not ensure an employee making adjustments to the line #15 cheese slicer machine performed and followed the established energy control procedures by; ensuring the machine was turned off [per 1910.147(d)(2) requirements], isolating the machine from the energy source(s) [(d)(3)], affixing a lockout device [(d)(4)(i)], and verifying de-energization and isolation had been accomplished [(d)(6)], prior to adjusting the machine.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View BIERY CHEESE CO.'s full OSHA safety record →