SIOUX FALLS, SD —
OSHA Inspection: BH CONSTRUCTION & HOMES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BH CONSTRUCTION & HOMES, LLC in 2505 SOUTH MOSS STONE AVENUE, SIOUX FALLS, SD 57108 (NAICS 238170). OSHA activity number 342840766.
Where did this inspection happen?
- Establishment
- BH CONSTRUCTION & HOMES, LLC
- Site address
- 2505 SOUTH MOSS STONE AVENUE
- City
- SIOUX FALLS
- State
- SD
- ZIP
- 57108
- Mailing
- 26963 464TH AVENUE, TEA, SD 57064
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $3326.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a)BH Construction & Homes, LLC at 2505 South Moss Stone Avenue, Sioux Falls, SD 57108: On or about and at times prior to December 18, 2017, the exposing employer did not ensure that each employee was protected from falls from heights, in that two employees were conducting siding operations on pump jack scaffolding with no fall protection system in place. This condition exposed employees to a fall hazard of approximately 12 feet 10 inches.
Recent events (2)
- — I (S) $2000
- — Z (S) $3326
1926.451 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: (a)BH Construction & Homes, LLC at 2505 South Moss Stone Avenue, Sioux Falls, SD 57108: On or about and at times prior to December 18, 2017, the employer did not ensure that each employee was protected from falls from heights, in that two employees were conducting siding operations on pump jack scaffolding that the edge of the scaffolding platform was 16 inches away from the wall being sided. This condition exposed the employees to a fall hazard of approximately 12 feet 10 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: (a)BH Construction & Homes, LLC at 2505 South Moss Stone Avenue, Sioux Falls, SD 57108: On or about and at times prior to December 18, 2017, the exposing employer did not ensure that each employee was protected from falls due to inadequate structural support, in that two employees were conducting siding operations on pump jack scaffolding with no base plates, mud sills or other adequate firm foundation in place. This condition exposed the employees to a fall hazard of approximately 12 feet 10 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface were not used. Crossbraces shall not be used as a means of access. (a)BH Construction & Homes, LLC at 2505 South Moss Stone Avenue, Sioux Falls, SD 57108: On or about and at times prior to December 18, 2017, the employer did not ensure that each employee was provided a safe means of access to the scaffolding system. Employees were using cross-braces as a means of access to the platform. This condition exposed employees to a fall hazard of approximately 12 feet 10 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a)BH Construction & Homes, LLC at 2505 South Moss Stone Avenue, Sioux Falls, SD 57108: On or about and at times prior to December 18, 2017, the exposing employer did not ensure that each employee that was working from scaffolding systems were trained to recognize the potential hazards associated with the work being done and the system being used. This condition exposed employees to fall hazards of approximately 12 feet 10 inches. Abatement Note: The training shall include the following elements at a minimum: (1)The nature of any electrical hazards, fall hazards, and falling object hazards in the work area; (2)The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used: (3)The proper use of the scaffold, and the proper handling of materials on the scaffold; (4)The maximum intended load and the load-carrying capacities of the scaffold used; and (5)Any other pertinent requirements of this subpart.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. (a)BH Construction & Homes, LLC at 2505 South Moss Stone Avenue, Sioux Falls, SD 57108: On or about and at times prior to December 18, 2017, the exposing employer did not ensure that each employee was protected from falls due to potentially inadequate structural support in that two employees were conducting siding operations on pump jack scaffolding without bottom or equivalent bracing. This condition exposed the employees to inadequate structural support and a potential fall hazard of approximately 12 feet 10 inches.
Recent events (2)
- — I (S) $1000
- — Z (S) $1663
1926.452 K04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(k)(4): Ladders used to support ladder jacks were not be placed, fastened, or equipped with devices to prevent slipping: (a)BH Construction & Homes, LLC at 2505 South Moss Stone Avenue, Sioux Falls, SD 57108: On or about and at times prior to December 18, 2017, the employer did not ensure that each employee was protected from falls due to potentially inadequate structural support, in that two employees were conducting siding operations on pump jack scaffolding system integrated with a ladder jack system where the ladder was not secure to prevent slipping. This condition exposed the employees to a fall hazard of approximately 12 feet 10 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at BH CONSTRUCTION & HOMES, LLC
TEA, SD—2025-01-30
BH CONSTRUCTION & HOMES, LLC
TEA, SD—2025-01-02
BH CONSTRUCTION & HOMES, LLC
SIOUX FALLS, SD—2018-08-08 00:00:00
BH CONSTRUCTION & HOMES, LLC
SIOUX FALLS, SD—2018-01-09 00:00:00
BH CONSTRUCTION & HOMES, LLC
View BH CONSTRUCTION & HOMES, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in SD
CLEAR LAKE, SD—2026-07-15
AEROTEK
YANKTON, SD—2026-07-14
EEI ENTERPRISE, LLC
SIOUX FALLS, SD—2026-07-14
S&T CONSTRUCTION, LLC
SIOUX FALLS, SD—2026-07-14
SAENZ CONSTRUCTION, LLC DBA TOP NOTCH CONSTRUCTION
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342840766.