CRESCENT, PA —
OSHA Inspection: PREMIER PAN COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PREMIER PAN COMPANY, INC. in 33 MCGOVERN BOULEVARD, CRESCENT, PA 15046 (NAICS 332215). OSHA activity number 343985974.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PREMIER PAN COMPANY, INC.
- Site address
- 33 MCGOVERN BOULEVARD
- City
- CRESCENT
- State
- PA
- ZIP
- 15046
- Mailing
- 33 MCGOVERN BOULEVARD, CRESCENT, PA 15046
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332215
- Employees
- 140
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.217 B13
- Issued
- Jun 18, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $10,229 · Current $5,115 Reduced
General-duty citation text
29 CFR 1910.217(b)(13): Control system(s) of mechanical power press(es) were not constructed so that a failure within the system would not prevent the normal stopping action from being applied to the press when required, but would prevent initiation of a successive stroke until the failure is corrected. (a) 854 Press, Model #8- 33 McGovern Boulevard, Crescent, PA: On or about April 12, 2019, the part revolution power press's brake failed causing the ram to fall and pin the operators hands between the ram and the dye set.
Recent events (3)
- — F (S) $5115
- — C (S) $10229
- — Z (S) $10229
1910.217 B14 II
- Issued
- Jun 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(14)(ii): Brake system monitoring of mechanical power press(es) was not installed so that it indicated when the performance of the braking system had deteriorated to the extent that the safety distance was not maintained. (a) 854 Press, Model #8- 33 McGovern Boulevard, Crescent, PA: On or about April 12, 2019, the part revolution power press's brake failed causing the ram to fall and pin the operators hands between the ram and the dye set; the brake system monitoring was not so installed to properly indicate a fault in the braking system.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Premier PAN Company, INC.