1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: LG HAUSYS AMERICA, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LG HAUSYS AMERICA, INC in 310 LG DR SE, ADAIRSVILLE, GA 30103 (NAICS 326191). OSHA activity number 344959614.

Watch LG Hausys America, INC — free Get an email when a new federal OSHA severe-injury report for LG Hausys America, INC is published. One employer, no account, unsubscribe in one click.
Site address
310 LG DR SE
City
ADAIRSVILLE
State
GA
ZIP
30103
Mailing
310 LG DR SE, ADAIRSVILLE, GA 30103
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326191
Employees
300
Ownership type
A

2 citations on file for this inspection.

1910.305 G02 III

Serious Gravity 5 12 instances 6 exposed
Issued
Penalty
Initial $12723.00 · Current $12723.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.  By the VT1 main crusher: On or about 10/06/2020, adequate strain relief was not provided on electrical connections at various points of the main crusher. Electrical tape was used in some of the connections while others the had the inner sheaths exposed, thus exposing employees who frequent the area to electrical hazards should the wiring be damaged or ripped out.
Recent events (2)
  • — I (S) $12723
  • — Z (S) $12723

1910.147 C06 I C

Deleted Repeat Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $53015.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.  LG Hausys at the Viatera plant: On or about 10/22/2020, and at times prior to, annual audits to evaluate the effectiveness of the company's machine specific energy control procedures were not completed as required. Energy sources used at the facility include; but are not limited to, electrical, pneumatic and hydraulic energy and the primary voltage used at the facility includes 480 volts phase 3 60Hz.  LG Hausys America Inc, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 1416767, citation number 1, item number 2 and was affirmed as a final order on 02/07/2020, with respect to a workplace located at 310 LG Drive SE. ADAIRSVILLE GA, 30103.
Recent events (2)
  • — I (R) $0
  • — Z (R) $53015

View LG HAUSYS AMERICA, INC's full OSHA safety record →