Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RCR HOME IMPROVEMENT, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RCR HOME IMPROVEMENT, INC in 213 HOWELL STREET, BELLMORE, NY 11710 (NAICS 236115). OSHA activity number 345497291.

Watch RCR Home Improvement, INC — free Get an email when a new federal OSHA severe-injury report for RCR Home Improvement, INC is published. One employer, no account, unsubscribe in one click.
Site address
213 HOWELL STREET
City
BELLMORE
State
NY
ZIP
11710
Mailing
1044 WILSON BLVD, CENTRAL ISLIP, NY 11722
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3108.00 · Current $2000.00 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) Worksite,  213 Howell Street , Bellmore NY -  Employee was using a 6ft. A-Frame Ladder in the closed position to install plywood on the south side of the house; on or about 8/21/2021.      The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3108

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3108.00 · Current $2000.00 Reduced
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:    a) Worksite, 213 Howell Street, Bellmore NY - Employee was using the top of a 6ft. A-Frame Ladder to install plywood on the south side of the house; on or about 8/21/2021.   NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3108

1926.1060 A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1865.00 · Current $900.00 Reduced
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:  a) Worksite, 213 Howell Street, Bellmore NY - Employee using a 6ft. A-Frame Ladder  to install plywood on the south side of a residential home was not provided with ladder training ; on or about 8/21/2021  Note: The employer is required to provide abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1865

View RCR HOME IMPROVEMENT, INC's full OSHA safety record →