Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RCR HOME IMPROVEMENT, INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of RCR HOME IMPROVEMENT, INC in 8 NYACK DRIVE, EAST NORTHPORT, NY 11731 (NAICS 236118). OSHA activity number 346746548.

Watch RCR Home Improvement, INC — free Get an email when a new federal OSHA severe-injury report for RCR Home Improvement, INC is published. One employer, no account, unsubscribe in one click.
Site address
8 NYACK DRIVE
City
EAST NORTHPORT
State
NY
ZIP
11731
Mailing
1044 WILSON BLVD, CENTRAL ISLIP, NY 11722
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3683.00 · Current $2208.00 Reduced
29 CFR  1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.  a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employees were installing Siding/Polar Wrap while working from a pump jack scaffold.  The scaffold platform extended approximately 4 feet past the support exposing employees to fall hazards while working approximately 13.5 feet above the ground; on or about 5/30/2023.   Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — R (S) $2208
  • — C (S) $3683
  • — Z (S) $3683

1926.451 F07

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3683.00 · Current $2208.00 Reduced
29 CFR  1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.  a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - Employees were exposed to fall hazards while installing Siding/Polar Wrap to a residential home from a pump jack scaffold.  The scaffold was not erected by a competent person; on or about 5/30/2023.    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — R (S) $2208
  • — C (S) $3683
  • — Z (S) $3683

1926.452 J02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3683.00 · Current $2208.00 Reduced
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  a) Worksite: 8 Nyack Drive, East Northport, NY 11731 -  Employees were installing Siding/Polar Wrap to a residential home while working from a pump jack scaffold that was not secured at the bottom; on or about 5/30/23.   Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — R (S) $2208
  • — C (S) $3683
  • — Z (S) $3683

View RCR HOME IMPROVEMENT, INC's full OSHA safety record →