NORTH CANTON, OH —
OSHA Inspection: HOOVER ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HOOVER ROOFING LLC in 4526 MASSILLON RD, NORTH CANTON, OH 44720 (NAICS 238160). OSHA activity number 345665434.
Where did this inspection happen?
- Establishment
- HOOVER ROOFING LLC
- Site address
- 4526 MASSILLON RD
- City
- NORTH CANTON
- State
- OH
- ZIP
- 44720
- Mailing
- 9833 BELLHAVEN, UNIONTOWN, OH 44685
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2486.00 · Current $2486.00
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On or about December 2, 2021, during the installation of roofing material at a job site located at 4526 Massillon Rd, N. Canton, Ohio 44720; the employer did not ensure employees working on a roof of a single family home were protected from a fall of approximately 10.2 feet by utilizing a fall protection system.
Recent events (1)
- — Z (S) $2486
1926.1053 B01
- Issued
- Penalty
- Initial $2486.00 · Current $2486.00
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about December 2, 2021 at the job site located at 4526 Massillon Rd, N. Canton, Ohio 44720; during the installation of roofing material on a residential roof, the employer did not ensure portable ladders extend 3 feet above the upper landing surface.
Recent events (1)
- — Z (S) $2486
More inspections at HOOVER ROOFING LLC
UNIONTOWN, OH—2023-11-20 00:00:00
HOOVER ROOFING LLC
CANTON, OH—2022-06-06 00:00:00
HOOVER ROOFING LLC
WASHINGTON, DC—2019-05-01 00:00:00
HOOVER ROOFING, LLC
CANTON, OH—2013-05-06 00:00:00
HOOVER ROOFING LLC
TALLMADGE, OH—2012-11-08 00:00:00
HOOVER ROOFING LLC
View HOOVER ROOFING LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source