COLORADO SPRINGS, CO —
OSHA Inspection: LINDSAY PRECAST, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LINDSAY PRECAST, INC. in 3330 E. LAS VEGAS ST., COLORADO SPRINGS, CO 80906 (NAICS 327390). OSHA activity number 345816326.
Where did this inspection happen?
- Establishment
- LINDSAY PRECAST, INC.
- Site address
- 3330 E. LAS VEGAS ST.
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80906
- Mailing
- PO BOX 5440, COLORADO SPRINGS, CO 80931
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 65
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $14502.00 · Current $10000.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Employees working on a walking-working surface with unprotected sides and edges 4 feet or more above lower levels, were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems: (a) On or about March 2, 2022, and at times prior to that date, employees were exposed to injuries from falls in excess of 4 feet while conducting daily maintenance on a Carder Concrete Model # 450 elevated concrete mixer without the benefit of fall protection systems being in place.
Recent events (2)
- — I (S) $10000
- — Z (S) $14502
1910.30 A03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.30(a)(3)(i): The employer did not train each employee in the nature of the fall hazards in the work area and how to recognize them: (a) On or about March 2, 2022, and at times prior to that date, the employer did not provide training to employees exposed to fall hazards on how to recognize and prevent them in the work area, in that employees were exposed to injuries from falls while conducting daily maintenance on a Carder Concrete Model # 450 elevated concrete mixer which was in excess of 4 feet above the lower surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 D03
- Issued
- Abate by
- Penalty
- Initial $14502.00 · Current $10000.00 Reduced
General-duty citation text
29 CFR 1910.146(d)(3): The employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to, the following: (a) On or about March 2, 2022, and at times prior to that date, the employer failed to develop and implement the means, procedures, and practices necessary for safe permit space entry operations for employees entering a permit-required confined space. Employees were entering a Carder Concrete Model #450 concrete mixer to perform clean out and maintenance activities, which contained uncontrolled mechanical hazards. An employee was seriously injured while working inside the mixer when it was turned on.
Recent events (2)
- — I (S) $10000
- — Z (S) $14502
1910.146 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(g)(1):The employer did not provide training so that all employees whose work is regulated by this section acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section: a) On or about March 2, 2022, and at times prior, employees were exposed to caught-in between and crushing hazards while working inside a permit required confined space (Carder Concrete Model #450 concrete mixer) without the benefit of adequate training on the recognition of hazards associated with permit required confined space entry and the means necessary to control those hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C09
- Issued
- Abate by
- Penalty
- Initial $14502.00 · Current $10000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(9): The employer or authorized employee did not notify affected employees before the lockout or tagout devices were applied or removed from the machine or equipment: a) On or about March 2, 2022, and at times prior, affected employees were exposed to crushing and caught-in between hazards while entering the Carder Concrete Mixer #450 to perform clean-out and maintenance resulting from not being notified the machine had a lockout or tagout device applied or removed.
Recent events (2)
- — I (S) $10000
- — Z (S) $14502
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $14502.00 · Current $10000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On or about March 2, 2022, and at times prior to that date, the employer did not evaluate the workplace to determine if its lockout/tag out (LO/TO) program and procedures were adequate to establish an effective locked out/tagged out condition of its machines, exposing employees to crushing and caught-in between hazards. While working inside a Carder Concrete Model #450 concrete mixer to perform clean out and maintenance activities, an employee was seriously injured when the machine was turned on.
Recent events (2)
- — I (S) $10000
- — Z (S) $14502
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $145027.00 · Current $110000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section: (a) On or about March 2, 2022, and at times prior to that date, the employer did not ensure that procedures were developed and utilized to control hazardous energy when employees were entering a Carder Concrete Model #450 concrete mixer to perform clean out and maintenance activities, resulting in an employee suffering serious injuries while working inside the concrete mixer when it was activated.
Recent events (2)
- — I (W) $110000
- — Z (W) $145027
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) On or about March 2, 2022, and at times prior, workers were not provided with specific information regarding the types and magnitude of hazardous energy, potential hazards and the means to perform a full and effective removal of hazardous energy present in the Carder Concrete Model #450 cement mixer, such as electrical, mechanical, and pressurized air.
Recent events (2)
- — I (S) $0
- — Z (W) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) On or about March 2, 2022, and at times prior to that date, the employer did not affix lockout/tagout devices to each energy isolating device, as required by this standard as well as the operator's manual, resulting in an employee suffering serious injuries while working inside the concrete mixer. Employees routinely entered the mixer to perform cleaning and maintenance without applying lockout/tagout devices.
Recent events (2)
- — I (S) $0
- — Z (W) $0
More inspections at LINDSAY PRECAST, INC.
COLORADO SPRINGS, CO—2023-06-23 00:00:00
LINDSAY PRECAST, INC.
COLORADO SPRINGS, CO—2019-08-12 00:00:00
LINDSAY PRECAST, INC.
COLORADO SPRINGS, CO—2017-03-30 00:00:00
LINDSAY PRECAST, INC.
ALACHUA, FL—2014-01-14 00:00:00
LINDSAY PRECAST, INC.
View LINDSAY PRECAST, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327390)
OGDEN, UT—2026-07-10
OLDCASTLE INFRASTRUCTURE, INC.
CHARDON, OH—2026-07-09
JAB SUPPLY CORPORATION
LINDON, UT—2026-07-07
NEW CAST STONE
ANDERSON, CA—2026-07-06
OUTDOOR CREATIONS INC.
MCKINNEY, TX—2026-07-01
QUIKRETE
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345816326.