WYNNEWOOD, OK —
OSHA Inspection: CVR COMMON SERVICES, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of CVR COMMON SERVICES, LLC in 906 S. POWELL AVE., WYNNEWOOD, OK 73098 (NAICS 324110). OSHA activity number 346722408.
Where did this inspection happen?
- Establishment
- CVR COMMON SERVICES, LLC
- Site address
- 906 S. POWELL AVE.
- City
- WYNNEWOOD
- State
- OK
- ZIP
- 73098
- Mailing
- 906 S. POWELL AVE., WYNNEWOOD, OK 73098
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324110
- Employees
- 509
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.119 F04
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $15625.00
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not implement safe work practices to provide for the control of hazards during operations such as opening process equipment. On or about May 23, 2023, at the Prime G Reboiler Pass 4 Control Valve at the Wynnewood Refinery in Wynnewood, Oklahoma, employees were exposed to fire and chemical release hazards when safe work practices that fully defined the scope and limitation of the work to be performed were not effectively implemented by the maintenance department.
Recent events (2)
- — I (S) $15625
- — Z (S) $15625
1910.119 J02
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment. a. On or about May 22, 2023, at the Wynnewood Refinery in Wynnewood Oklahoma, employees were exposed to fire and chemical release hazards when the employer did not establish and implement written troubleshooting procedures for employees tasked to troubleshoot an automated valve. b. On or about May 23, 2023, at the Wynnewood Refinery in Wynnewood Oklahoma, employees were exposed to fire and chemical release hazards when the employer did not establish and implement written procedures for employees tasked to break open an automated valve and physically maneuver the valves internal components.
Recent events (2)
- — I (S) $0
- — Z (S) $15625
1910.119 J03
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(j)(3): The employer did not train each employee involved in maintaining the on-going integrity of process equipment in an overview of that process and its hazards and in the procedures applicable to the employee's job tasks to assure that the employee can perform the job tasks in a safe manner. On or about May 23, 2023, at the Wynnewood Refinery in Wynnewood Oklahoma, employees were exposed to fire and chemical release hazards when the employees were not trained to perform maintenance work on the automated valve of the chemical process equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $15625
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $25000.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. On or about May 23, 2023, at the Prime G Reboiler Pass 4 Control Valve, Wynnewood Refinery in Wynnewood Oklahoma, employees did not affix lockout or tagout devices to each energy isolating device prior to mechanical disassembly of the valve. This exposed the employees to fire and chemical release hazards.
Recent events (2)
- — I (S) $25000
- — Z (S) $15625
1910.147 D06
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment the authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished. On or about May 23, 2023, at the Prime G Reboiler Pass 4 Control Valve at the Wynnewood Refinery in Wynnewood Oklahoma, employees did not verify the equipment being maintained had been isolated and de-energized. This exposed the employees to fire and chemical release hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $15625
More inspections at CVR COMMON SERVICES, LLC
WYNNEWOOD, OK—2024-06-25 00:00:00
CVR COMMON SERVICES, LLC
COFFEYVILLE, KS—2023-10-19 00:00:00
CVR COMMON SERVICES, LLC
WYNNEWOOD, OK—2023-06-23 00:00:00
CVR COMMON SERVICES, LLC
COFFEYVILLE, KS—2023-03-29 00:00:00
CVR COMMON SERVICES, LLC
COFFEYVILLE, KS—2023-03-18 00:00:00
CVR COMMON SERVICES, LLC
View CVR COMMON SERVICES, LLC's full OSHA safety record →
More inspections in this industry (NAICS 324110)
TORRANCE, CA—2026-07-15 00:00:00
TORRANCE REFINING COMPANY LLC
NOME, TX—2026-07-13 00:00:00
EXXON MOBIL OIL CORPORATION
EL SEGUNDO, CA—2026-06-30 00:00:00
CHEVRON U.S.A. INC.
EL SEGUNDO, CA—2026-06-30 00:00:00
CHEVRON U.S.A. INC.
TRAINER, PA—2026-06-26 00:00:00
MONROE ENERGY, LLC
More inspections in OK
TULSA, OK—2026-07-15 00:00:00
LA UNION 7 LLC
STILLWATER, OK—2026-07-13 00:00:00
LATSHAW DRILLING COMPANY
BROKEN ARROW, OK—2026-07-10 00:00:00
AMERICAN WHEATLEY
TINKER AFB, OK—2026-07-09 00:00:00
U.S. DEPARTMENT OF DEFENSE, TINKER AIR FORCE BASE
OCHELATA, OK—2026-07-08 00:00:00
WALMART, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346722408.