Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PREMIER BUILDING RESTORATION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PREMIER BUILDING RESTORATION, INC. in 1900 JOHN F KENNEDY BLVD, PHILADELPHIA, PA 19103 (NAICS 238140). OSHA activity number 347554388.

Watch Premier Building Restoration, INC. — free Get an email when a new federal OSHA severe-injury report for Premier Building Restoration, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1900 JOHN F KENNEDY BLVD
City
PHILADELPHIA
State
PA
ZIP
19103
Mailing
529 BETHLEHEM PIKE, ERDENHEIM, PA 19038
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
48
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $8067.00 · Current $7260.00 Reduced
1926.501(b)(10)  "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.   a) Jobsite: 1901 John F Kennedy Blvd, Philadelphia, PA - On or about June 3, 2024, the employer did not ensure employees staging materials along the unprotected edges of the roof of the 20 story high rise residential apartment building, approximately 230 feet above ground level, were protected from falling by the use of a fall protection system.
Recent events (2)
  • — I (O) $7260.3
  • — Z (S) $8067

View PREMIER BUILDING RESTORATION, INC.'s full OSHA safety record →