Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: VORTEQ COIL FINISHERS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VORTEQ COIL FINISHERS, LLC in 930 ARMOUR RD, OCONOMOWOC, WI 53066 (NAICS 332812). OSHA activity number 347596082.

Watch Vorteq Coil Finishers, LLC — free Get an email when a new federal OSHA severe-injury report for Vorteq Coil Finishers, LLC is published. One employer, no account, unsubscribe in one click.
Site address
930 ARMOUR RD
City
OCONOMOWOC
State
WI
ZIP
53066
Mailing
930 ARMOUR RD, OCONOMOWOC, WI 53066
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332812
Employees
55
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $16131.00
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) On or about June 28, 2024, an employee was servicing the "S" Coater Machine on Coater Line 1, and did not utilize the specific developed lockout/tagout procedure prior to commencement of cleaning the backer rollers, exposing the employee to ingoing nip point created by backer rollers.
Recent events (2)
  • — C (S) $16131
  • — Z (S) $16131

1910.147 D02

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  (a) On or about June 28, 2024, an employee  servicing the "S" Coater Machine on Coater Line 1, did not deenergize and lock out the machine and rollers prior to commencement of cleaning the backer rollers, exposing the employee to ingoing nip point created by backer rollers.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

View VORTEQ COIL FINISHERS, LLC's full OSHA safety record →