FRANKLIN PARK, IL —
OSHA Inspection: VORTEQ COIL FINISHERS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of VORTEQ COIL FINISHERS, LLC in 11440 ADDISON AVE, FRANKLIN PARK, IL 60131 (NAICS 332812). OSHA activity number 348167016.
Where did this inspection happen?
- Establishment
- VORTEQ COIL FINISHERS, LLC
- Site address
- 11440 ADDISON AVE
- City
- FRANKLIN PARK
- State
- IL
- ZIP
- 60131
- Mailing
- 11440 ADDISON AVE, FRANKLIN PARK, IL 60131
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 37
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $16550.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1) The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees engaged in maintenance activities 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Maintenance Shop - On or about April 7, 2025, the employer did not ensure the operator of the Sharp 1760K lathe removed any wearable items such as gloves during operation of the lathe. An employee suffered a three-finger amputation when their glove because caught during sanding operations. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $16550
- — Z (S) $16550
More inspections at VORTEQ COIL FINISHERS, LLC
VALENCIA, PA—2026-06-24 00:00:00
VORTEQ COIL FINISHERS, LLC
FRANKLIN PARK, IL—2025-02-05 00:00:00
VORTEQ COIL FINISHERS, LLC
VALENCIA, PA—2024-08-16 00:00:00
VORTEQ COIL FINISHERS, LLC
OCONOMOWOC, WI—2024-07-02 00:00:00
VORTEQ COIL FINISHERS, LLC
FRANKLIN PARK, IL—2024-04-02 00:00:00
VORTEQ COIL FINISHERS, LLC
View VORTEQ COIL FINISHERS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332812)
COLUMBIA, SC—2026-07-15 00:00:00
77575 - AZZ PRECOAT METALS
COLUMBIA, SC—2026-07-15 00:00:00
77574 - PRECOAT METALS
WICHITA, KS—2026-07-10 00:00:00
DIVERSIFIED SERVICES, INC.
SHARON, PA—2026-07-09 00:00:00
NLMK SHARON COATING, LLC
CUDDY, PA—2026-07-08 00:00:00
SUPERIOR POWDER COATING INC
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
FOREST PARK, IL—2026-07-17 00:00:00
CONSERVATION OF SCULPTURE & OBJECTS STUDIO, INC.
BLUE ISLAND, IL—2026-07-17 00:00:00
PROFLOW PUMPING SOLUTIONS
Source