OMAHA, NE —
OSHA Inspection: THE JAMES SKINNER LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of THE JAMES SKINNER LLC in 4657 G STREET, OMAHA, NE 68117 (NAICS 311812). OSHA activity number 347844847.
Where did this inspection happen?
- Establishment
- THE JAMES SKINNER LLC
- Site address
- 4657 G STREET
- City
- OMAHA
- State
- NE
- ZIP
- 68117
- Mailing
- 4657 G STREET, OMAHA, NE 68117
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 965
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.30 A01
- Issued
- Abate by
- Penalty
- Initial $13005.00 · Current $9000.00 Reduced
General-duty citation text
29 CFR 1910.30(a)(1): The employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart before any employee is exposed to a fall hazard. On or about October 28th, 2024, employees engaged in maintenance and oven lighting operations located at 4657 G Street, Omaha, Nebraska 68117, were exposed to fall hazards in that employees were working on top of the Blue Oven without receiving fall protection training. Instances of failure include but are not limited to: A.) An employee exposed to fall hazards when lighting the Blue Oven. B.) Multiple employees exposed to fall hazards when performing maintenance on the Blue Oven.
Recent events (5)
- — P (S) $9000
- — F (S) $9000
- — F (S) $9000
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.132(d)(1):The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment. On or about October 25th, 2024, employees engaged in oven lighting operations located at 4657 G Street, Omaha, Nebraska 68117, were exposed to electrical hazards in that the employer failed to assess oven lighting operations for the Blue Oven. As a result of not conducting an assessment and providing employees with the proper PPE when performing this task, an employee was shocked when attempting to light the Blue Oven.
Recent events (5)
- — P (O) $2500
- — F (O) $2500
- — F (O) $2500
1910.335 A01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.335(a)(1)(i):Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: On or about October 25th, 2024, employees engaged in oven activities located at 4657 G Street, Omaha, Nebraska 68117, were exposed to electrical hazards in that an employee was shocked when attempting to light the Blue Oven for production. The employee shocked was not provided with electrically rated gloves, electrically rated sleeves, or an ARC flash hood.
Recent events (5)
- — P (S) $0
- — F (S) $0
- — F (S) $0
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $11000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy. On or about October 28th, 2024, employees engaged in maintenance activities located at 4657 G Street, Omaha, Nebraska 68117, were exposed to pneumatic and thermal hazards in that the employer failed to identify the missing energy sources on the Blue Oven.
Recent events (5)
- — P (S) $11000
- — F (S) $11000
- — F (S) $11000
1910.147 D04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(ii):Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position: On or about October 28th, 2024, employees engaged in maintenance operations located at 4657 G Street, Omaha, Nebraska 68117 were exposed to pneumatic and thermal energy source hazards in that the employer failed to require employees to affix their LOTO devices on the Blue Oven prior to commencing work on it. Instances of failure include, but are not limited to: A.) Pneumatic Air Pressure (PSI) Energy Source B.) Thermal Energy Source
Recent events (5)
- — P (S) $0
- — F (S) $0
- — F (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $11000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The employer is failing to protect employees from hazards associated with LOTO on the Blue Oven. This was most recently documented on or about October 25th, 2024, at 4657 G Street, Omaha, Nebraska 68117. The employer failed to conduct a periodic inspection on the Blue Oven. The Blue Oven LOTO procedure failed to identify pneumatic and thermal as energy sources on the written procedure.
Recent events (5)
- — P (S) $11000
- — F (S) $11000
- — F (S) $11000
1910.147 F02 I
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $11000.00 Reduced
General-duty citation text
29 CFR 1910.147(f)(2)(i):When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures: On or about October 28th, 2024, employees engaged in maintenance activities located at 4657 G Street, Omaha, Nebraska 68117, were exposed to hazards associated with LOTO on the Blue Oven. The host employer and contractor failed to inform each other of their respective LOTO procedures prior to commencing work on the Oven.
Recent events (5)
- — P (S) $11000
- — F (S) $11000
- — F (S) $11000
1910.332 B02
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $11000.00 Reduced
General-duty citation text
29 CFR 1910.332(b)(2):Additional requirements for unqualified persons. Employees who are covered by paragraph (a) of this section but who are not qualified persons shall also be trained in and familiar with any electrically related safety practices not specifically addressed by 1910.331 through 1910.335 but which are necessary for their safety. On or about October 25th, 2024, employees engaged in oven operations located at 4657 G Street, Omaha, Nebraska 68117, were exposed to electrical hazards in that the Blue Oven Operator did not receive electrical training from their employer prior to handling energized circuits on the Blue Oven. As a result, an employee was shocked.
Recent events (5)
- — P (S) $11000
- — F (S) $11000
- — F (S) $11000
1910.335 A02 I
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $11000.00 Reduced
General-duty citation text
29 CFR 1910.335(a)(2)(i):When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: On or about October 25th, 2024, employees engaged in oven operations located at 4657 G Street, Omaha, Nebraska 68117, were exposed to electrical hazards in that the Blue Oven operator was shocked when attempting to prepare the Blue Oven for operations. The employer failed to provide the oven operator with insulated tools or equipment prior to handling energized circuits.
Recent events (5)
- — P (S) $11000
- — F (S) $11000
- — F (S) $11000
1910.335 A02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.335(a)(2)(ii):Protective shields, protective barriers, or insulating materials were not used to protect each employee from shock, burns, or other electrically related injuries while that employee was working near exposed energized parts. On or about October 25th, 2024, employees engaged in oven operations located at 4657 G Street, Omaha, Nebraska 68117, were exposed to electrical hazards in that the oven operators were not provided with with protective shields or insulating materials when working on or near energized circuits. As a result, an employee was shocked.
Recent events (5)
- — P (O) $0
- — F (O) $0
- — F (O) $0
1910.335 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.335(b)(2):Barricades were not used in conjunction with safety signs where it was necessary to prevent or limit employee access to work areas in which employees were exposed to uninsulated energized conductors or circuit parts: On or about October 25th, 2024, employees engaged in oven operations located at 4657 G Street, Omaha, Nebraska 68117, were exposed to electrical hazards in that safety signs were not used to when employees were exposed to uninsulated energized circuits on the Blue Oven.
Recent events (5)
- — P (S) $0
- — F (S) $0
- — F (S) $0
More inspections at THE JAMES SKINNER LLC
OMAHA, NE—2025-07-15
THE JAMES SKINNER LLC
OMAHA, NE—2025-01-16
THE JAMES SKINNER LLC
OMAHA, NE—2024-12-19
THE JAMES SKINNER LLC
OMAHA, NE—2024-11-06 00:00:00
THE JAMES SKINNER LLC
OMAHA, NE—2024-08-20 00:00:00
THE JAMES SKINNER LLC
View THE JAMES SKINNER LLC's full OSHA safety record →
More inspections in this industry (NAICS 311812)
LONGVIEW, WA—2026-07-10
WA317992033 - UNITED STATES BAKERY DBA FRANZ FAMILY BAKERIE
GLENDALE, CA—2026-07-08
FREUND BAKING COMPANY
YONKERS, NY—2026-07-07
GREYSTON BAKERY INC.
JACKSONVILLE, OR—2026-07-02
317744689 - CURLY TOP BAKE SHOP LLC
MERIDEN, CT—2026-07-02
PUB DISTRIBUTION HOLDER, LLC
More inspections in NE
OMAHA, NE—2026-07-10
WINGSTOP
LINCOLN, NE—2026-07-01
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30
PATRIOT PLUMBING, HEATING & AC
BLAIR, NE—2026-06-30
NATUREWORKS LLC
EDISON, NE—2026-06-30
AG VALLEY COOP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347844847.