1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: CHACON DRYWALL, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHACON DRYWALL, LLC in 7950 UNION CENTER BOULEVARD, WEST CHESTER, OH 45011 (NAICS 238310). OSHA activity number 347933707.

Watch Chacon Drywall, LLC — free Get an email when a new federal OSHA severe-injury report for Chacon Drywall, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CHACON DRYWALL, LLC
Site address
7950 UNION CENTER BOULEVARD
City
WEST CHESTER
State
OH
ZIP
45011
Mailing
5424 PLANTATION RIDGE, CHARLOTTE, NC 28217
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $12744.00 · Current $6372.00 Reduced
29 CFR 1926.451(g) Fall protection. (1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.     a) On December 12, 2024, the employer failed to ensure that an employee was utilizing a fall protection system when performing roofing work while standing on the mid-rail of an elevated scissor lift. As a result, an employee was exposed to a fall hazard of 16'9'' above the ground below.
Recent events (2)
  • — I (S) $6372
  • — Z (S) $12744

1926.501 B01

Repeat Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $25487.00 · Current $12744.00 Reduced
29 CFR 1926.501(b)(1):"Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a) On December 12, 2024, the employer failed to ensure that employees performing roofing activities on a commercial roof with unprotected sides and edges were utilizing a fall protection system. As a result, employees were exposed to a fall height of 16'9''.    Chacon Drywall, LLC was previously cited for a violation of this occupational safety and health standard, 29 CFR 1926.501 (b)(1), which was contained in OSHA inspection number 1758621, citation number 1, item number 2 and was affirmed as a final order on 10/17/2024, with respect to a workplace located at 151 N Stewart Road, Liberty, Missouri, 64068.
Recent events (2)
  • — I (R) $12743.5
  • — Z (R) $25487

View CHACON DRYWALL, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347933707.