PARK CITY, KS —
OSHA Inspection: PRATT (LOVE BOX) LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRATT (LOVE BOX) LLC in 5700 N HYDRAULIC, PARK CITY, KS 67219 (NAICS 322211). OSHA activity number 348627134.
Where did this inspection happen?
- Establishment
- PRATT (LOVE BOX) LLC
- Site address
- 5700 N HYDRAULIC
- City
- PARK CITY
- State
- KS
- ZIP
- 67219
- Mailing
- 5700 N HYDRAULIC, PARK CITY, KS 67219
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 380
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 II
- Issued
- Penalty
- Initial $14187.00 · Current $14187.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about December 03, 2025, at Pratt Industries, Love Box Company, located at 5700 North Hydraulic, Park City, Kansas, the employer failed to protect employees from struck-by and crushing hazards. The employer failed to adequately develop written lockout/tagout procedures for employees to follow while servicing the Bobst 924 - Cardboard folding machine. The equipment specific lockout/tagout procedures did not include: (A) A listing of all energy sources including but not limited to pneumatic, electrical, and gravity. The employer did not document the counterweight being stuck as a gravity energy source in the machine specific lockout/tagout procedures. (B) The specific location of all listed energy sources. The counterweight was not identified in the lockout/tagout specific documentation as a energy source. (C) The specific devices to be used to de-energize each energy source including but not limited to locks, chains, pins and other lockout devices, etc. The employer did not provide additional equipment to secure the counterweight stored energy in the vertical position during maintenance. (D) The specific procedures for the temporary removal or transfer of lockout/tagout devices for the purpose of testing or positioning, or clearing jams. The employer did not provide guidance on how to properly manage the counterweight sticking in an elevated position. (E) The specific steps to test and verify the effectiveness of the energy control devices and energy control measures prior to beginning or re-engaging in work.
Recent events (2)
- — C (S) $14187
- — Z (S) $14187
More inspections at PRATT (LOVE BOX) LLC
LINCOLN, NE—2019-02-14 00:00:00
PRATT (LOVE BOX), LLC.
OKLAHOMA CITY, OK—2018-01-10 00:00:00
PRATT "LOVE BOX" LLC
OKLAHOMA CITY, OK—2017-01-19 00:00:00
PRATT "LOVE BOX" LLC
OKLAHOMA CITY, OK—2015-07-23 00:00:00
PRATT "LOVE BOX" LLC
View PRATT (LOVE BOX) LLC's full OSHA safety record →
More inspections in this industry (NAICS 322211)
SAVAGE, MN—2026-07-08
111557 - BF NELSON CORPORATION
WEST CHESTER, OH—2026-07-08
GEORGIA PACIFIC CORRUGATED LLC
ALBERT LEA, MN—2026-07-01
111514 - INTERSTATE PACKAGING CORPORATION
STURTEVANT, WI—2026-07-01
ND PACKAGING LLC
FILER CITY, MI—2026-06-29
PACKAGING CORPORATION OF AMERICA
More inspections in KS
WICHITA, KS—2026-07-10
DIVERSIFIED SERVICES, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
WICHITA, KS—2026-07-09
FIGEAC AERO NORTH AMERICA, INC.
PITTSBURG, KS—2026-07-08
CDL ELECTRIC
WICHITA, KS—2026-07-08
IBT, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348627134.