OSHA Inspection: PRATT (LOVE BOX) LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRATT (LOVE BOX) LLC in 5700 N HYDRAULIC, PARK CITY, KS 67219 (NAICS 322211). OSHA activity number 348627134.

Watch Pratt (Love BOX) LLC — free Get an email when a new federal OSHA severe-injury report for Pratt (Love BOX) LLC is published. One employer, no account, unsubscribe in one click.
Site address
5700 N HYDRAULIC
City
PARK CITY
State
KS
ZIP
67219
Mailing
5700 N HYDRAULIC, PARK CITY, KS 67219
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
322211
Employees
380
Ownership type
A

1 citation on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $14187.00 · Current $14187.00
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    On or about December 03, 2025, at Pratt Industries, Love Box Company, located at 5700 North Hydraulic, Park City, Kansas, the employer failed to protect employees from struck-by and crushing hazards. The employer failed to adequately develop written lockout/tagout procedures for employees to follow while servicing the Bobst 924 - Cardboard folding machine. The equipment specific lockout/tagout procedures did not include:  (A) A listing of all energy sources including but not limited to pneumatic, electrical, and gravity. The employer did not document the counterweight being stuck as a gravity energy source in the machine specific lockout/tagout procedures. (B) The specific location of all listed energy sources. The counterweight was not identified in the lockout/tagout specific documentation as a energy source.  (C) The specific devices to be used to de-energize each energy source including but not limited to locks, chains, pins and other lockout devices, etc. The employer did not provide additional equipment to secure the counterweight stored energy in the vertical position during maintenance.   (D) The specific procedures for the temporary removal or transfer of lockout/tagout devices for the purpose of testing or positioning, or clearing jams. The employer did not provide guidance  on how to properly manage the counterweight sticking in an elevated position. (E) The specific steps to test and verify the effectiveness of the energy control devices and energy control measures prior to beginning or re-engaging in work.
Recent events (2)
  • — C (S) $14187
  • — Z (S) $14187

View PRATT (LOVE BOX) LLC's full OSHA safety record →