Caught in running equipment or machinery, unspecified · Traumatic injuries and disorders, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Heraeus Electro-Nite Co.,LLC, 541 S. Industrial Drive, HARTLAND, WISCONSIN 53029
on — Traumatic injuries and disorders, unspecified, affecting the nonclassifiable.
Final narrative
Employee was caught by a machine when reaching for wire inside. Employee was hospitalized and required surgery.
On December 19, 2023, an employee was setting up a copper wire drawing machine when his left ring finger was pinched between a copper wire and a machine part. The employee's finger was partially amputated.
An employee was checking the gusset seal on a machine. He moved to the next cross sealer and the machine activated, causing an amputation to a left-hand finger. The employee was hospitalized.
An employee was evaluating a coiling machine to verify that the blade was present inside it. The machine's weld function was activated, and the machine crushed the employee's fingers, resulting in the amputation of the left middle and ring fingers.
An employee was using a hand tool to cut a mooring line at a marina to demonstrate equipment to customers. The hand tool broke and struck the employee in their left eye, lacerating the cornea.
An employee had just gone through a roll-up door and closed it. The rope used to pull the door down caught her foot and she fell, breaking her left kneecap.
An employee was retrieving a bottle from inside a permeability plugging tester machine when the machine began moving. The employee sustained a left ring fingertip amputation.
An employee was changing the bottom die on a hydraulic power crimper. Their left thumb was crushed between the two die components when the crimper engaged, resulting in thumb fractures.
A chemist was finishing a reaction. He added paraformaldehyde to a Grignard solution in a 5-liter glass jacketed reactor. The reaction mixture over-pressurized and the reactor shattered, spreading shards of glass throughout the room. The chemist sustained lacerations to the chest and thigh.
The injured employee was assisting five other employees with bracing a wall panel that was being stood up. Another employee slipped on frost on the floor surface. The employees went to evacuate the area in anticipation of the wall panel falling over. The injured employee went to jump through a window opening within the wall panel and their lower half was crushed by the falling wall panel. The employee sustained a fractured pelvis.
An employee was using a vertical band saw to cut a thick piece of rubber material. While being cut, the material shifted, causing the employee s right hand to contact the moving blade. The employee's thumb was amputated below the knuckle. The employee was hospitalized, undergoing surgery.
A production sanitation employee was pre-rinsing an incline conveyor and noticed cheese stuck between the belt idler. The employee went to remove the cheese and their glove got caught and pulled their left forearm into the conveyor. The employee's arm was fractured. The machine was not locked out/tagged out at the time.
An employee was on a ladder, taking measurements for a new gutter installation. The ladder slipped out from under him and both he and the ladder fell to the ground. He was hospitalized with seven broken ribs and a broken clavicle.
An employee was unloading a truck for a delivery job. While moving boxes in the truck, the employee tripped over a pallet and fell out of the truck to the ground, resulting in four broken ribs.