Direct exposure to electricity, greater than 220 volts · Electrical burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Revere Copper Products, Inc., 1 Revere Park, ROME, NEW YORK 13440
on — Electrical burns, unspecified, affecting the hand(s), unspecified.
Final narrative
An employee working on a 480V electrical panel dropped a metal cage, which created an arc flash and burned the employee's hand.
An employee was setting up a furnace and lighting the torch on the furnace when they sustained burns from a flashback flame. The employee was hospitalized with burns to their head, face, chest, arms, and armpit area.
An employee was unloading a truck with a forklift. The employee's right hand was caught between the forklift's roll cage and a computer keyboard's metal swing arm. The little finger was crushed at the knuckle and the ring finger was lacerated.
An employee was installing a ground wire to a power transmission pole. The ground wire contacted an energized portion of a cut-out, causing an arc-flash. The employee was hospitalized with second degree burns to their chest and arms.
An employee was connecting a utility transformer for underground service to a home. The employee's impact drill went across two connection bars with 240 volts of potential, creating an arc flash. The employee sustained burns to the face and eyes due to the arc flash and molten aluminum.
On December 15, 2023, at 9:15 AM, an employee was changing 60-amp fuses in a 480-volt panel when an arc flash occurred. The employee was hospitalized with burns to both hands.
An employee was polishing a bar on the lathe with sandpaper when the bar wrapped around the employee's glove and pulled it off. The employee sustained fractures to their index finger, wrist, and a knuckle.
An employee was using an electrical meter to troubleshoot an electrical drive system. While removing the probe, the employee made contact with the bus and was shocked. The employee sustained burns to their fingers and a dislocated shoulder.
An employee was setting up a furnace and lighting the torch on the furnace when they sustained burns from a flashback flame. The employee was hospitalized with burns to their head, face, chest, arms, and armpit area.
An employee was using a metal bar tied to a nylon strap attached to a jib crane to tighten a metal ring on a heated extrusion press. The metal bar flew off and struck the employee in the left forearm, fracturing it.
An employee was troubleshooting the lift table of the automated take-up mechanism on the jacket extrusion line. He was able to get the table to raise up, at which point it engaged and lowered. The employee's leg was pinned between the lift table and the concrete floor. His ankle was broken and he was hospitalized, requiring surgery.
An employee was operating a battery-powered broom to clean demolition debris off the top of the outermost bridge girder. The girder was approximately 11 feet above the demolition scaffold below. The employee fell approximately 8 feet to wind bracing below. The employee was hospitalized with a pelvis/tailbone fracture. Fall protection was in place at the time.
An employee slipped while descending in a stairwell, fell, and suffered multiple contusions/bruises to the head, neck, shoulders, knees, and back. She was hospitalized.