Direct exposure to electricity, unspecified · Electrical burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Kenco Plastics, Inc., 509 S. McKenna, POTEAU, OKLAHOMA 74953
on — Electrical burns, unspecified, affecting the leg(s), unspecified.
Final narrative
An employee was repairing a molding press when his right leg came in contact with a live conductor, causing him to experience loss of consciousness and burns due to electrocution. He was hospitalized for his injuries.
An employee was installing a 15-amp breaker in an electrical panel when a 12-gauge ground wire touched the positive busbar of the panel, resulting in an arc flash. The employee sustained a second-degree burn to their left hand.
An employee was repairing an HVAC system in the drop tile ceiling of a conference room when they were shocked, causing them to fall from the ladder. The employee sustained burns to their right middle and ring fingers.
An employee was replacing a contactor inside an electrical panel attached directly to a press. The press itself was receiving power from another main panel. After replacing the contactor, the employee flipped the switch and an arc flash occurred, burning the employee's elbow, bicep, and neck.
An employee was attempting to switch a medium-voltage primary cable and install a 200-amp fuse barrel. The employee contacted the bottom of the switch gear cradle for the fuse barrel, causing an arc blast. The electricity entered the employee s left hand and exited his big toes, resulting in electric shock and burns to the left hand, arm, shoulder, and both feet. The employee was hospitalized.
On December 6, 2023, an employee of Duke Energy was working on a single-phase 120-/240-volt parallel service re-tap when a secondary flash occurred in an underground service. The employee suffered a second-degree burn to the face and was hospitalized.
More severe injuries in this industry (NAICS 326199)
An employee was operating a drill and tap machine. He was placing a part with his right hand and removing a part coming in on the left side. He saw a part that was crooked and went to straighten it. The machine clamped down on his left index finger, degloving the top part of the finger and resulting in a partial amputation.
An employee was performing maintenance on a roll cutting machine in a warehouse. The employee was removing excess grease from the bearings when the machine's chain caught their right index finger. The fingertip was amputated by the chain and sprocket.
During fiberglass work, an employee mixed a methyl ethyl ketone peroxide (MEKP) catalyst with a cobalt chemical that they thought was a dye. A chemical reaction occurred, resulting in an explosion. The employee sustained second-degree burns on his back and a blister on his right arm.
An employee was walking when she tripped over a box on the ground and fell. The employee was hospitalized with a severe dislocation to the hip and leg that required surgery.
An employee was helping to move a 1,300-pound coil on a cart. The steel caster hit a crack in the concrete, the weld holding the caster onto the cart broke, and the coil and cart tipped over onto the employee. He was hospitalized with a laceration on his forehead and a pelvic fracture on his right side.
An employee was working in the food service warehouse when he experienced chest pain, difficulty breathing, and lost consciousness. The employee sustained carbon monoxide poisoning.
An employee was cutting a piece of metal rod with a metal cutting machine. His right middle finger became caught between the rod and the machine's table. The employee's fingertip was partially amputated.
An employee was working at her desk. She went to stand up and fell to the floor beside the desk. The employee sustained a hip displacement and required surgery.
An employee was processing wood boards at a chop saw when the saw malfunctioned and the blade cut her left hand and fingers. She was hospitalized and her little finger was surgically amputated.