Struck against moving part of machinery or equipment · Cuts, lacerations
At a glance
Federal OSHA recorded a severe workplace injury
at ALL AMERICAN POLY CORPORATION, 40 TURNER PL, PISCATAWAY, NEW JERSEY 08854
on — Cuts, lacerations, affecting the hand(s), unspecified.
Final narrative
An employee was clearing debris from the line. The blower did not come to a complete stop and the employee's left hand was lacerated.
An employee was evaluating an issue with a shaft in a winder. The employee's left index, middle, and ring fingers got caught between the belt drive and sprocket, resulting in one finger amputation at the first joint.
Two employees were installing a new plastic roll on a winder machine. One of them was pulling the film with her left hand from the output side of the machine; the film and the rotating member of the winder caught her left hand, breaking both bones in her left forearm.
An employee was drilling a hole in a can containing aerosol spray glue. The can exploded, causing second-degree burns to the employee's arms, face, and neck.
An employee was activating the pneumatic release button on the spindle of the winder when the spool spun and the employee's middle fingertip was caught against part of the spindle cradle and resulting in an avulsion.
An employee was descending a fixed caged ladder when he missed the top rung and began to fall. He grabbed onto a vertical member of the cage assembly to catch himself and caught his right pinky in a 1/2-inch gap between the upright and a toe board section. His right pinky fingertip was amputated.
An employee was operating a strip saw. As the employee shut off the saw, their right index and middle fingertips were amputated by the blade before it came to a complete stop.
An employee was using a table saw to cut a piece of wood for wall framing. The wood jumped, causing the employee's hand to move toward the saw, amputating their left index finger and causing a laceration on their hand.
An employee was operating a trim saw. While trying to free a jammed board she had just cut, she came into contact with the running saw blade, which amputated her right thumb.
A subcontracted engineer was advising maintenance how to make a modification to the embossing roll system on a new line. Maintenance was bringing the motor and gearbox down with a crane. The load shifted when it was a few inches from the ground. The engineer went to catch/maneuver the gearbox and the fingers on his left hand were crushed between the I-beam base of the gearbox and the concrete floor. A finger was amputated.
On July 30, 2025, an employee was assisting co-workers in using a hoist to position an injection molding tool onto a work table. As the tool was being lowered, the slide section shifted, trapping and amputating the employee's right thumb tip.
An employee was manually lifting a film roll when their right middle fingertip was pinched between the roll and a metal beam, resulting in a fingertip amputation.
At about 10:00 a.m. on July 13, 2025, an employee was cleaning the adhesive from running rollers using a rag soaked in cleaning solvent to prevent contamination. The rag was caught between two rollers and pulled the employee's right hand between the rollers. The employee sustained right hand crushing injuries, de-gloving injuries (palmer and dorsal sides), and fractures. The employee was hospitalized and required surgery. The machine was not locked out/tagged out at the time.
An employee working on a sheet line was removing masking from the underside of plastic sheeting that was being lifted by a vacuum lift. The plastic sheet measured 4 feet wide, 14 feet long, and approximately 1 inch thick, and it weighed approximately 300 pounds. The vacuum lost suction and dropped the plastic sheet onto the employee's arm, pinning it between two sheets and resulting in a broken right forearm.
An employee was installing fence posts when they stepped into a recently dug hole that was not visible due to rainfall. The employee's leg was fractured.
An employee assisted in cleaning material from a conveyor pit. After the pit was cleaned, the employee proceeded to replace metal safety plates to ensure other employees did not fall into the pit. While replacing one of the last plates, the employee mis-stepped and fell approximately 5 feet into the pit. The employee was hospitalized with back/side bruising, elbow bruising, bone bruises, and/or fractured ribs.