Ignition of vapors, gases, or liquids · Heat (thermal) burns, unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Trans Tech Energy, Inc., 1130 N Scenic Hwy , LAKE WALES, FLORIDA 33853
on — Heat (thermal) burns, unspecified, affecting the multiple body parts, n.e.c..
Watch Trans Tech Energy, Inc. — freeGet an email when a new federal OSHA severe-injury report for Trans Tech Energy, Inc. is published. One employer, no account, unsubscribe in one click.
Final narrative
An employee was performing a vacuum procedure on a bulk 30,000-gallon propane tank. He was using an air compressor to blow air into the base of the container to create a tornado effect that subsequently vacuums the propane from the tank.
A tool ignition source ignited the flammable gas, burning legs and face of the employee, who was 18 to 36 feet away from the opening.
An employee was cleaning a cordless drill. As they applied brake fluid to the drill and pulled the trigger, the fluid ignited. The employee suffered burns to the face, hands, and arms.
An employee was spraying glue to the floor of an enclosed cargo trailer. The fumes made contact with the heater causing a flash fire. The employee suffered burns to their face and right hand.
An employee was replacing a valve in the gas line to the fryer. The shutoff valve malfunctioned resulting in a gas leak that then ignited. The employee sustained burns requiring hospitalization.
An employee was operating an aerial work platform. While the employee was maneuvering the lift through a set of double doors, their head was caught between the door frame and the platform's vertical mast. The employee suffered a skull fracture that required surgery.
An employee was transporting used filter media (containing pyrophoric iron sulfide) from an inlet gas separator in the bed of a truck. The material ignited. While the employee was removing items from the truck bed, a gas can was exposed to the fire and off-gassing vapors ignited. The employee suffered first- and second-degree burns to both arms, the chest, the neck, and the right ear. The employee was hospitalized.
An employee was using a pipe threading machine to thread a 2-inch diameter gas pipe during the rebuilding of a gas meter. The pipe was in a vise mounted on the back of the crew truck. A few pieces of metal chips or shavings caused the threading machine to jam. The employee started to back the pipe up, but it jammed in that direction as well. While reaching to pull the handle back up into place to try and start again, the machine rotated about an inch and pinched his middle fingertip against the edge of the truck s back step. The employee's fingertip was partially amputated without loss of bone.
The injured employee was manually lowering a ramp on a heavy equipment trailer with the assistance of another employee. The injured employee was standing behind the trailer ramp. After removing the safety pins, the ramp descended quickly and struck the injured employee, causing them to fall to the ground. The employee was hospitalized with fractures to their sternum and L1 vertebra.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.