Struck by object or equipment, unspecified · Soreness, pain, hurt-nonspecified injury
At a glance
Federal OSHA recorded a severe workplace injury
at TENNESSEE VALLEY AUTHORITY, 7900 METROPOLIS LAKE ROAD, WEST PADUCAH, KENTUCKY 42086
on — Soreness, pain, hurt-nonspecified injury, affecting the back, including spine, spinal cord, unspecified.
Final narrative
An employee was troubleshooting a leak in an air blast muffler when the muffler sheared loose from the flange and struck the employee in the back.
HospitalizedBack, including spine, spinal cord, unspecifiedMachine, tool, and electric parts, unspecified
More severe injuries at TENNESSEE VALLEY AUTHORITY
Two employees were lifting and installing the lance tube into place using a combination of chain falls and manual manipulation. While moving the lance tube into place, the employee on one end lost their grip on the tube and it fell to the grating. Since the lance tube was also suspended from a chain fall, the other end went up and caught the injured employee's right hand between the lance tube and an I-beam. The injured employee suffered lacerations across the top of their little, ring and middle fingers, and fractures to their little and ring fingers. The employee was hospitalized.
An employee was utilizing a truck mounted crane to remove a trailer hitch pin. As the employee was assisting with loading the haul trailer, the tongue of the trailer fell on the employee's foot. The employee's right foot was crushed.
An employee was moving a load to a work table. The load shifted and pinched the employee's left little finger against the table. The employee underwent a medical amputation to the finger.
An employee was inspecting components and contacts of a transformer load tap changer in a substation. When the equipment rotated, it caught the employee's left middle finger, causing an amputation at the nail bed.
An employee was checking the function of newly installed actuators when they were struck by a pressurized release pipe. The employee suffered fractures to the orbital socket and shoulder, requiring hospitalization.
An employee was completing a service call and looking at a water pump when the pump cover plate struck their forehead. The employee sustained a forehead laceration and fracture requiring hospitalization.
An employee was removing chains from a steel tube. A sorting hook attachment was caught on the staging area cross member. When he raised the chains, the sorting hook snapped back and struck the employee's face causing a fractured jaw.
An employee was in the sawmill basement using a push broom and shovel to clean wood chips and sawdust. The employee's right arm was struck by a wooden board between the wrist and elbow, resulting in a fracture.
More severe injuries in this industry (NAICS 221119)
Employees were preparing to replace a primary electrical cable. While two of the employees were working to remove the cable on one side of a switchgear, they came into contact with a wrench and the outside part of the switchgear. One employee suffered an electrical shock.
An employee was installing personal protective grounds at a substation when their hand contacted the end of the ground that was not energized, but induced voltage was created by wind and shocked them. This resulted in a burn on their thumb.
At about 9:35 a.m. on March 18, 2024, an employee was conducting maintenance on a non-operational fan controller in a switchgear room. The employee pulled the controller and began installing a new one. The employee was electrocuted, suffering third-degree burns to the right hand and fingers as well as burns to the right forearm, and was hospitalized.
A mail carrier was delivering mail when aggressive dogs approached. The dog's owner tried to restrain the dogs but one dog broke loose and the mail carrier pepper sprayed that dog. The dog's owner then pushed the mail carrier and he fell on the pavement and injured his neck. The mail carrier was hospitalized.
An employee was installing a fall protection system on a flat roof when they tripped and became entangled in the warning line. They fell approximately 30 feet to the ground below. The employee sustained fractures.
An employee was outside assembling a 500-ton crane. The employee was connecting the rigging to the boom. He leaned forward to attach the lifting plate on the side of the boom and lost balance while bending over. He fell to the ground approximately 10 feet below, landing on his elbow. The employee was hospitalized with a fractured elbow that required surgery.
An employee was using a winch to secure a barge to a dock. The cable of an adjoining winch snapped and struck his left side, causing blunt force trauma and internal injuries to his abdomen.