Other fall to lower level, unspecified · Fractures
At a glance
Federal OSHA recorded a severe workplace injury
at ECRI Institute, 5200 Butler Pike, PLYMOUTH MEETING, PENNSYLVANIA 19462
on — Fractures, affecting the multiple trunk locations.
Final narrative
An employee was installing a computer cable in the ceiling while working from a ladder. While he was putting the ceiling tile back in place, he slipped and fell to the floor, breaking ribs and his back.
An employee was on an A-frame ladder retrieving materials from a shelf. He slipped and fell and his leg got caught in the ladder rungs, breaking his left tibia.
An employee was unloading materials from a flatbed trailer when they fell from the trailer and landed on the ground. The employee sustained a fractured left leg.
An employee was unloading appliances at a customer location for delivery. The employee was moving a water heater to be placed on the liftgate when he stepped backward and fell to the ground. The employee sustained rib and back injuries.
An employee was operating a horizontal belt sanding machine that rotates a metal sanding belt. The employee switched hands while the belt transitioned from left to right. When the machine's speed was adjusted, the employee s left hand was pulled into the machine and crushed. The employee was hospitalized and required surgery.
An X-ray machine had lost power and an employee went to replace the power supply. While replacing a cable on the power supply assembly, the employee's right hand contacted the grounding terminals coming out of the back of the power supply assembly and they received an electric shock. The employee was hospitalized.
On March 19, 2025, an employee was retrieving a medical specimen from the back of a vehicle. When he turned to enter the building, he either tripped over something or lost his footing and fell due to an incline in the pavement. The employee was hospitalized with a head abrasion and injuries to his right shoulder and right hip.
Employees were pulling a chemical sample from a device (sample port). The sample wouldn't come out because there were two samples in the port. The employees then turned off and deenergized the machine to 0 pounds per square inch. They unscrewed the top of the machine to retrieve the stuck samples when a small amount of pressure caused liquid to squirt out and onto one of the employee's face shields as the lid was removed. The employee was hospitalized due to chemical exposure.
An employee was walking around a boiler recovery tank when they stepped into an uncovered U-drain filled with hot water. The employee sustained second-degree burns to their right leg and the top of their foot.
An employee was walking into the motor control center (MCC) room when his right ring finger was caught in the hinge of a doorway. He sustained an open phalanx fracture, which resulted in a partial amputation above the first knuckle.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was pulling down a broken skid with a forklift. When the employee backed up the forklift to get the forks out of the skid he pulled down, he contacted the forks of another parked forklift, fracturing both of his legs. He was hospitalized.
An employee was carrying cups back to the kitchen when her foot got caught on a cart and she fell face-first. During the fall, a piece of glass from a cup cut the inside of her mouth, severing an artery. She also sustained a laceration on her lower lip. The employee was hospitalized.