An employee was walking down a corridor when he opened a metal door that had an electrical current due to a pinched wire from temporary lighting in the corridor. He received an electrical shock.
HospitalizedBODY SYSTEMSDoors, except garage and vehicle
An employee was welding clips onto the end of the bridging of a wall, then installing bolts through the clips to the wall. As the employee lowered his rod holder down into the lift basket, the rod contacted the basket and energized it. As the employee leaned forward, they contacted the basket and grounded joist, resulting in first- and second-degree electrical burns to the stomach, back, and arms.
An employee was on the ground preparing to receive a wire stringing steel rope being flown by a helicopter. The employee grabbed the steel line and was shocked by electricity from the line on his right hand. The employee was hospitalized and required surgery for nerve damage to his hand.
An employee was pulling a line through a light pole when it contacted an uninsulated line. The employee was shocked and sustained burns that required hospitalization.
An employee was in a bucket truck drilling a hole into a utility pole when a conductor located above the employee broke free from the pole and fell onto the equipment. The employee suffered second-degree burns to the right side of their face.
More severe injuries in this industry (NAICS 532412)
An excavator bucket was being removed. An employee was pulling a snap ring to remove a pin and lost his grip. The high-tension snap ring recoiled and his left middle fingertip was amputated by the snap ring.
An employee was walking between service bays. He came into contact with a trailer hitch, which was sticking out of the back of a lawn mower, and fell to the concrete floor. He landed on his right side and suffered a broken hip.
An employee was taking a scissor lift off a flatbed trailer. While using the remote operator controls and walking alongside the lift, the wheel of the lift turned in the wrong direction, causing it to strike the employee and roll over his left ankle. The employee was hospitalized with two broken bones in his ankle.
An employee was working on an excavator's tracks. He was swinging a sledgehammer to finish pushing a metal tractor pin into the track links. A hammer-blow caused a piece of the pin to fly off, ricochet, and embed itself in his buttock. He was hospitalized, requiring surgery.
An employee was picking up crane pads to put onto their trailer. Their finger got pinched between pads, resulting in an amputation involving the loss of skin.
An employee was helping a coworker transport a tall palm tree with a mini skid steer. The employee was severely shocked by a high-voltage electrical wire above the ground.
An employee was retrieving a Christmas tree from a shelf using a ladder. He missed a step and fell to the concrete floor. He sustained injury to his head and wrist.
An employee was operating an agricultural tractor during sugarcane harvesting. The employee sustained a lumbar sprain due to vibration or motion from the tractor.
An employee was moving a 3-ton condensing unit, strapped down on a dolly, out of a garage. The strap broke, causing the employee to fall backward onto the brick pavered driveway. The employee suffered injury to a spinal ligament in the neck.