Struck against moving part of machinery or equipment · Amputations
At a glance
Federal OSHA recorded a severe workplace injury
at National Beef, 2000 E. Trail, DODGE CITY, KANSAS 67801
on — Amputations, affecting the finger(s), fingernail(s), unspecified.
Final narrative
An employee was using a rip saw to cut a beef product when the blade partially amputated the outside tissue of his left pinky finger (no tendon or bone damage).
An employee was conducting maintenance and checking alignment on a conveyor belt in the fabrication area of the plant. The employee's sleeve was pulled into the conveyor belt, resulting in an amputation that required hospitalization and surgery.
An employee was cleaning in the pack off area of the facility using a high pressure hot water hose. The employee was walking with the hose when the hose got caught on the conveyor frame in the area and the employee lost their grip on the hose. The hose fell to the ground and the employee was sprayed with hot water. Hot water got inside their boot and the employee sustained first and second degree burns to their left foot.
An employee was pushing cattle in the pens when a steer jumped the 10-foot gate and struck the employee causing multiple facial fractures and a laceration across the nose. The employee was hospitalized.
An employee was operating a strip saw. As the employee shut off the saw, their right index and middle fingertips were amputated by the blade before it came to a complete stop.
An employee was using a table saw to cut a piece of wood for wall framing. The wood jumped, causing the employee's hand to move toward the saw, amputating their left index finger and causing a laceration on their hand.
An employee was operating a trim saw. While trying to free a jammed board she had just cut, she came into contact with the running saw blade, which amputated her right thumb.
An employee was scraping dried glue from the top lid of a hot glue pot. His left hand slipped and came into contact with the hot glue. He then suffered burns to his hands and fingers as he tried to remove the glue. He was hospitalized.
An employee was in a scissor lift approximately 20 feet above the ground to place a plastic tarp on a catwalk in order to catch condensation. They positioned the lift opposite the work area and stepped out of the scissor lift onto an I-beam. The employee fell from the I-beam to the ground. The employee was hospitalized with a skull fracture on the right side of their head and injuries to the chest and both eyes.
A maintenance employee was called to look at a pallet conveyor machine where a chain had fallen off a sprocket wheel. When the employee grabbed the loose chain, a light sensor caused the machine to restart. This created a pinch point between the chain and sprocket that caught the employee's left little finger. The finger was surgically amputated at the second knuckle.
The injured employee was standing by one of the stationary computers along the wall. There was a half-pallet located approximately 3 feet behind the employee that consisted of 12-pound boxes stacked six boxes high. A forklift was transporting a pallet that came in contact with the stationary pallet behind the injured employee, causing four boxes to fall and contact their legs. The injured employee was hospitalized with leg injuries.
An employee was using a box strapping machine to place straps on boxes when his right middle finger was caught in the machine, resulting in an open fracture to the distal phalanx.
An employee was working to remove a product blockage from a piece of equipment. The employee was struck by a metal bar near the deck of the pin mixer equipment and sustained blunt force trauma to the torso.
An employee was moving a rack onto a lower conveyor in the south heat treat area when their finger got caught between the part tray and the rollers, resulting in a fingertip fracture and amputation.
An employee was climbing a ladder to get on top of the breakroom. The ladder slipped, causing him to fall to the ground. The employee sustained fractures to his upper back, left foot, and ankle.
Two employees were removing a circuit breaker. The injured employee was using wrenches in the removal process. One of the wrenches contacted an adjacent door, resulting in an arc flash. The employee suffered burns to their neck, face, and ear, as well as momentary vision loss due to the flash.
An employee bent over to pick up a rubber mat from the ground. When he grabbed the corner of the mat, a rattlesnake hidden under it bit his left middle finger near the first knuckle. He was hospitalized.