105,313Records 71,083Employers 85,290Hospitalizations 27,770Amputations 2015-01-01 2025-10-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

DMI Columbus, LLC

Caught in running equipment or machinery during regular operation · Amputations

Federal OSHA recorded a severe workplace injury at DMI Columbus, LLC, 1600 Northside Industrial Blvd, COLUMBUS, GEORGIA 31904 on — Amputations, affecting the fingertip(s).

An employee was operating a drill press when the drill bit caught his glove and pulled his right index finger into the moving drill bit. His right index fingertip was amputated.

Amputation Fingertip(s) Drills-stationary

DMI Columbus, LLC

An employee fell off an 8-foot ladder and fractured his hip on the concrete floor.

DMI Columbus, LLC

An employee was burned on the hands and feet while breaking slag loose from the side of Furnace-A with a slag rod.

View DMI Columbus, LLC's full OSHA safety record →

Pall Corporation

An employee was operating a machine when a wire pulled his right glove resulting in amputation of the index and middle fingertips.

Koch Foods of Cincinnati

An employee was grinding chicken when their right index fingertip was caught in the grinder and amputated.

Stella-Jones Corporation

An employee was sharpening peeler blades when their shirt was caught in the grinding wheel. The employee sustained tendon damage and a crushed right hand.

Mack Manufacturing, Inc.

An employee was passing through a large metal door when the door closed on the employee, resulting in a cracked rib.

Nutmeg Container Corporation

An employee was preparing to cut lumber on a panel saw when the clamp engaged and caught the employee's left middle finger, resulting in a fingertip amputation.

Benton Foundry, Inc.

An employee was realigning two halves of a core box on a core-making machine. Pneumatic pressure released, causing the core box to close on the employee's right thumb. The thumb tip was amputated between the nail and the knuckle.

American Cast Iron Pipe Company

An employee was performing maintenance/electrical work inside a substation, and used a ladder to access the top of a panel box. The employee fell 8-9 feet from the top of the panel box to the ground. The employee was hospitalized with fractures to their ribs and a shoulder injury.

NIBCO INC.

An employee's hand was caught in a pinch point in the area of a conveyor for a flask running out of a foundry molding machine. The employee's ring finger was crushed and partially amputated at the base.

American Castings, LLC

An employee noticed a block was out of place under the weighted mold frame. The employee used another block to push the block out and replace it. When the block came out, the frame came down on his right ring and little fingers. The employee sustained a fracture and partial amputation to the ring fingertip.

OSCO Industries Inc.

An employee was using a fork truck to move a tub containing molten iron that had been drained from the cupula. The tub tipped over and the molten metal came in contact with water. This caused the molten iron to splash back and burn the employee's upper torso.

GS II Building Products, Inc.

An employee was helping to lift the grating from a floor draining system when the grating slipped and landed on his hand, resulting in the amputation of his right middle finger at the first joint.

US Battery Manufacturing Company, Inc

A casting machine jammed. An employee's hand was caught in the machine, where a belt line caught and amputated the tip of his finger.

Alfa Insurance

During a workshop meeting in a hotel, an employee heard a drilling noise, so he walked outside to see what it was. An explosion occurred (possible gas line) and his face, ear, and hair were burned. He also fell and sustained a pelvic fracture.

EMORY UNIVERSITY HOSPITAL

An employee slipped on condensation on a walkway in a parking garage. She fell and suffered a closed fracture to the neck of the left femur.

Bull Moose Tube