Federal OSHA recorded a severe workplace injury
at BriSco Corp, 64 Centennial Blvd, HIGHLANDS RANCH, COLORADO 80129
on — Fractures, affecting the multiple body parts, unspecified.
Final narrative
An employee was painting on top of a scissor lift platform that was extended 19 feet when the lift went over a ramp incline and became unstable, tipping over. The employee impacted the ground, suffering broken ribs and fractured vertebrae.
HospitalizedMultiple body parts, unspecifiedAerial lifts, scissor lifts-except truck-mounted
An employee was painting from the third step of a 6-foot ladder. As the employee descended the ladder, their foot missed the second step and they fell to the ground, resulting in a broken ankle.
An employee was operating a sit-down type of material handling equipment (MHE). They were turning the MHE with the clamp attachment in the air when the MHE fell over onto its right side. The employee's right foot was caught under the battery cover of the MHE. The employee sustained a chemical burn from the battery and a fractured right ankle.
An employee was driving an unloaded forklift outside a building. During a left turn, the forklift drove off the paved area onto an unpaved surface, became unstable, and tipped over. The employee was pinned under the forklift and suffered two broken leg bones and a broken hip.
An employee was trimming tree branches from an aerial lift. As they were maneuvering the aerial bucket lift from inside, the truck drove over soft ground and tipped over. The bucket lift fell to the ground with the employee tied off inside, resulting in rib fractures.
More severe injuries in this industry (NAICS 238320)
An employee was on a 12-foot extension ladder while painting the wall and soffit area of a pavilion less than 6 feet off the ground. The employee was using a sprayer when he fell off ladder and landed on his arm on the dirt clay ground. The employee sustained a dislocated elbow and fractures to his right arm and wrist that included an open fracture. The employee was hospitalized and required surgery.
An employee was blasting a water tower. They fell approximately 60 feet off a suspended scaffold and sustained broken vertebrae, a compound fracture of the tibia, a fractured heel, and a rupture to their liver. The employee was hospitalized.
An employee was sandblasting paint from a water tower when the blasting media sprayed across their forearm, resulting in an elbow injury that required hospitalization.
An employee was working from a boom lift, painting wood trim at a second-story roof level. The lift drove over an unmarked dry well, tipped, and catapulted the employee to the ground. The employee sustained fractures to their heels and vertebrae. Fall protection was not being worn at the time of the incident.
On October 2, 2025, an employee was ascending a ladder attached to a scaffold structure approximately 10 feet high. While climbing up, he lost his grip on a rung and fell to the ground, landing on his shoulder. He was hospitalized with fractures to his collarbone and shoulder.
An employee was delivering materials. He was doing his pre-delivery inspection on the roof of the jobsite (a warehouse) when he fell through a plexiglass skylight. He landed on his feet on the concrete floor 14 feet below. The employee sustained fractures to his spine, left ulnar/radius, and right heel. The employee required surgery.
An employee was removing packaging from a roll of printing substrate. The blade of their utility knife got stuck. The employee used both hands to free the knife and the blade partially amputated their left little fingertip.
A concrete batch plant operator was assisting with clearing spoil piles using a skid steer. The skid steer backed into a stationary screen plant. The employee's left little finger was crushed between the controls of the skid steer and the screen plant, resulting in a fracture and laceration. The employee's finger was surgically amputated.
An employee was standing on an extension ladder, using a torquing tool to remove bolts that secured blades to a rotor. When the torquing tool activated, its reaction arm came around and pinched the employee's right middle finger against a lifting eye. His fingertip was amputated.